针对发电机出口大电流互感器现场检定条件的局限性、操作的复杂性,传统升流器校验方法以及间接试验方法均不能满足现场检定要求,本文研制了一种适用于发电机出口大电流互感器现场检定的装置,为大电流互感器现场检定提供了解决方案。
In view of the limitations of the on-site verification conditions and the complexity of the operation of the large current transformer at the outlet of the generator,the traditional current riser verification methods and indirect test methods can not meet the requirements of the on-site verification.This paper develops a device suitable for the on-site verification of the large current transformer at the outlet of the generator,which provides a solution for the on-site verification of the large current transformer.
作者
许蔺
叶加星
Xu Lin;Ye Jiaxing(Nanjing Sanxin Power Supply Service Co.,Ltd.,Nanjing Jiangsu 210000;Jiangsu Frontier Electric Technology Co.,Ltd.,Nanjing Jiangsu 211102)
出处
《中国仪器仪表》
2023年第3期64-67,共4页
China Instrumentation
关键词
电流互感器
误差检定
调压系统
Current transformer
Error verification
Voltage regulating system