摘要
主要介绍了某化纤公司循环流化床锅炉的基本情况,并就循环流化床锅炉的连排、定排排污情况进行了说明,该公司通过加装列管式换热器、板式换热器,管道改造等措施,对排污余热进行了的再回用,有效降低了能耗,提高了公司的经济效益。
This paper mainly introduces the basic situation of the circulating fluidized bed boiler in a chemical fiber company,and describes the continuous and fixed blowdown of the circulating fluidized bed boiler,the waste heat of sewage discharge is reused by adding tubular heat exchangers,plate heat exchangers and pipe transformation,which effectively reduces energy consumption and improves the economic benefit of the company.
作者
朱洪鑫
梁松华
章四夕
庄耀中
陈祖彬
崔利
ZHU Hong-xin;LIANG Song-hua;ZHANG Si-xi;ZHUANG Yao-zhong;CHEN Zu-bin;CUI Li(Xinfengming Group Co.,Ltd.,Zhejiang,Tongxiang 314500;College of Materials and Textile Engineering,Jiaxing University,Zhejiang,Jiaxing 314001)
出处
《聚酯工业》
CAS
2023年第3期50-52,共3页
Polyester Industry
基金
浙江省“高层次人才特殊支持计划”2021R53016。
关键词
循环流化床锅炉
排污控制
余热回用
circulating fluidized bed boiler
blowdown control
waste heat recovery