摘要 首先对带肋异形截面K形相贯焊接节点进行缩尺模型试验,分析了节点在复杂受力工况下的应变发展过程,随后建立并验证了带肋异形K形相贯节点有限元模型。通过有限元计算对比分析了带肋节点和不带肋节点的应力分布、破坏模式和极限承载力,最后计算比较了节点在不同内外加劲厚度条件下的极限承载力。结果表明内、外加劲能够有效降低节点相贯区域应力,带肋节点相贯区达到材料断裂应变而发生破坏,带肋节点的极限承载力为不带肋节点的1.8倍,增大加劲板的厚度也可一定程度增大节点极限承载力。 A scaled model test of a stiffened K-joint with special-shaped section is carried out firstly,and then a finite element model of the K-joint is built and verified.This model is used to analyze the stress distribution,failure mode and ultimate bearing capacity of the stiffened and unstiffened K-joints.Finally,the ultimate bearing capacity of the Kjoints under different internal and external stiffening thicknesses are calculated and compared.The results show that internal and external stiffening can effectively reduce the stress in the intersecting area of the K-joint.The intersecting area of the stiffened K-joint reaches the material fracture strain and fails,and the ultimate bearing capacity of the stiffened K-joint is 180%as that of the unstiffened K-joint.Increasing the thickness of the stiffening plate can also slightly increase the ultimate bearing capacity of the K-joint.
作者 李春权 周锋 包侗 王伟 应天益 岳贵平 LI Chunquan;ZHOU Feng;BAO Tong;WANG Wei;YING Tianyi;YUE Guiping(Sinohydro Bureau 7 Co.,Ltd.,Chengdu 610213,China;State Key Laboratory of Disaster Reduction in Civil Engineering,Tongji University,Shanghai 200092,China;Shanghai Municipal Engineering Design Institute(Group)Co.,Ltd.,Shanghai 200093,China)
出处 《建筑钢结构进展》 CSCD 北大核心 2023年第4期58-67,共10页 Progress in Steel Building Structures
基金 国家自然科学基金(51820105013)。
关键词 K形节点 静力性能 加劲相贯节点 有限元分析 极限承载力 K-joint static performance stiffened joint finite element analysis ultimate bearing capacity
  • 相关文献

参考文献12

二级参考文献155

共引文献248

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部