摘要 三极管在汽车传感器、控制器电路中应用十分广泛,本文介绍了一项相关的实验室比对活动中的不确定度评定。评定的参数为三极管放大倍数,三极管放大倍数属于温度敏感参数,在进行不确定度评定时需要关注环境因素,开展高低温试验测定温度系数,同时在国内检测实验室中该参数普遍采用了自动化测量系统,该参数由系统间接计算,测量精度无法直接从仪器说明书获得。整体不确定度评定需要采用直接测量模型的A类评定,与温度试验、灵敏系数间接计算的B类评定相结合的方式进行。 Triodes are widely applied to the sensor and controller circuits in the automobile.This paper introduces the uncertainty evaluation in a relational laboratory comparison activity.The parameter to be measured is the triode magnification.The triode magnification is a temperature sensitive parameter.When evaluating the uncertainty,we must pay attention to the environmental factors and carry out temperature tests to determine the temperature coefficient.In another hand,the automatic measurement systems are widely used in domestic testing laboratories.The magnification is calculated indirectly by these systems,and the measurement accuracy cannot be obtained directly from the instrument manual.The class A method of direct measurement model and class B method of indirect calculation using temperature test results and sensitivity coefficient are combined to evaluate the uncertainty of the magnification.
作者 迟雷 桂明洋 谷亚敏 陈龙坡 安伟 CHI Lei;GUI Ming-yang;GU Ya-Min;CHEN Long-Po;AN Wei(The 13th Research Institute,CETC,Shijiazhuang 050051;National semiconductor Device Inspection and testing Center,Shijiazhuang 050051)
出处 《环境技术》 2023年第4期69-73,共5页 Environmental Technology
关键词 实验室比对 不确定度 半导体器件 三极管 放大倍数 laboratory comparison measurement uncertainty semiconductor device triode Magnification
  • 相关文献

参考文献6

二级参考文献12

共引文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部