WMS温度测量中谐波信号锁相放大器的设计 被引量:1

Design of Harmonic Signal Lock-In Amplifier in WMS Temperature Measurement
下载PDF
导出
摘要 在波长调制光谱技术(Wavelength Modulation Spectroscopy,WMS)温度测量中,传统的锁相放大器测量谐波信号的振幅必须对被测信号及参考信号的相位单独进行调整。针对这一问题,设计了一种基于高精度平衡调制器AD630进行同步相敏检测的谐波信号的双锁相放大器。与传统的锁相放大器相比,所提双锁相放大器利用正交双通道的平方和检测,可以避免被测信号与参考信号进行严格的相位匹配问题。利用Multisim软件构建仿真模型,包括前置高通滤波器、正交双通道的相敏检波器、低通滤波器等部分。理论计算和仿真结果表明,所提方法能够准确检测微弱一次、二次、四次谐波信号的幅度,检测误差小于5%,具有电路简单、运行速度快、线性度高等优点,能够满足WMS温度测量工程应用。 When measuring the temperature by wavelength modulation spectroscopy(WMS),the traditional lock-in amplifier must adjust the phase of the measured signal and the reference signal separately when measuring the amplitude of the harmonic signal.Therefore,this paper designs a dual-lock-in amplifier based on a high-precision balanced modulator AD630 for synchronous phase-sensitive detection of harmonic signals.Compared with conventional,the proposed dual-lock-in amplifiers can avoid strict phase matching between the measured signal and the reference signal by quadrature dual-channel sum-of-squares detection.Multisim software is used to build the simulation model,including pre-high-pass filter,quadrature dual-channel phase-sensitive detector,low-pass filter and so on.Theoretical calculation and simulation results show that the proposed method can accurately detect the amplitude of weak first,second and fourth harmonic signals,and the detection error is less than 5%.It has the advantages of simple circuit,fast running speed and high linearity,and it can meet the engineering application of WMS temperature measurement.
作者 闫佳伟 张丕状 倪沛东 石浩男 YAN Jiawei;ZHANG Pizhuang;NI Peidong;SHI Haonan(School of Information and Communication Engineering,North University of China,Taiyuan 030051,China)
出处 《测试技术学报》 2023年第3期214-220,共7页 Journal of Test and Measurement Technology
关键词 波长调制光谱技术(WMS) AD630 锁相放大 相敏检测 wavelength modulation spectroscopy(WMS) AD630 phase locked amplification phase sensitive detection
  • 相关文献

参考文献3

二级参考文献20

  • 1涂兴华,刘文清,张玉钧,董凤忠,王敏,王铁栋,王晓梅,刘建国.CO和CO_2的1·58μm波段可调谐二极管激光吸收光谱的二次谐波检测研究[J].光谱学与光谱分析,2006,26(7):1190-1194. 被引量:26
  • 2陈刚,张方正,潘时龙.一种新型分布反馈半导体激光器的多信号直调性能研究[J].光子学报,2013,42(9):1-7.
  • 3YE Wei-lin, ZHENG Chuan-tao, YU Xin, et al. Design and performances of a mid-infrared CH4 detection device with novel three-channel-based LS-FTF self-adaptive denoising structure [J]. Sensors and Actuators B, Chemical, 2011, 155(1) : 37- 45.
  • 4ZHENG Chuan-tao, YE Wei-lin, LI Guo-lin, et alo Performance enhancement of mid-infrared CH4, detection sensor by optimizing an asymmetric ellipsoid gas-cell and reducing voltage-fluctuation: Theory, design and experiment [J]. Sensors and Actuators B: Chemical, 2011, 160(1): 389- 398.
  • 5KOSKINEN V, FONSEN J, KAUPPINEN J, et al. Extremely sensitive trace gas analysis with modern photoacoustic spectroscopy [J]. Vibrational Spectroscopy, 2006, 42(2) : 239-242.
  • 6LIANG L, CONG M, YU H, etal. A DSP lock-in amplifier based on Simulink[C]. 2010 2nd International Conference on Information Science and Engineering (ICISE), 2010, 6379- 6382.
  • 7DE M A, FERRI G, D' AMICO A, et al. A fully-analog lock-in amplifier with automatic phase alignment for accurate measurements of ppb gas concentrations[J]. Sensors Journal, 2012, 12(5): 1377-1383.
  • 8张景超,管立君,肖长江,褚衍平.基于谐波检测原理的双光路CH_4检测研究[J].光电子.激光,2007,18(12):1442-1444. 被引量:15
  • 9王仁宝,冯红艳.基于数字信号处理器的激光光谱瓦斯监测系统[J].光电子.激光,2010,21(1):38-41. 被引量:24
  • 10焦斌亮,李素静.锁相放大器及其相关检测的仿真分析[J].电子技术(上海),2008,0(1):110-112. 被引量:9

共引文献23

同被引文献10

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部