摘要
中风、脑瘫患者因对下肢运动控制存在缺陷导致步态异常。设计一款气动踝足矫形器来预防足下垂等行动障碍。将踝关节位置和足底压力作为输入信号,采用模糊逻辑控制器(FLC)控制输出电压。监测和记录步行测试实验中控制器的输入和输出,结果表明基于模糊逻辑的踝足矫形器能在行走时提供辅助,有助于防止足下垂。
Patients with stroke and cerebral palsy have abnormal gait due to deficiencies in motor control of the lower extremities,and a pneumatic anklefoot orthosis is designed to prevent mobility disorders such as foot drop.Based on the ankle joint position and plantar pressure as input signals,a fuzzy logic controller(FLC)was used to control the output voltage.The inputs and outputs of the controller were monitored and recorded during walking test experiments,and the results showed that the fuzzy logicbased anklefoot orthosis can provide assistance during walking and help prevent foot drop.
作者
蒲文
华伟
Pu Wen;Hua Wei(College of Electronics and Information Engineering,Sichuan University,Chengdu 610065,China)
出处
《现代计算机》
2023年第8期117-120,共4页
Modern Computer
关键词
踝足矫形器
足下垂
模糊逻辑控制
anklefoot orthosis
foot drop
fuzzy logic controller