室内公共环境空气净化消毒机的研究设计 被引量:1

Research and Design of Indoor Public Environment Air Purifyingand Disinfecting Machine
下载PDF
导出
摘要 空气净化消毒机利用高压静电场净化消毒和紫外线杀菌的原理,通过机体的触摸屏、手机小程序或PC远程控制的智能控制方式,对空气进行净化的同时也对各种病毒、细菌以及其他病原体等有害物质进行多重灭杀。结果表明:空气净化消毒机可实现人机共存,具有可移动、智能控制、安全可靠、净化量大、净化消毒率高、所需时间短的优点。对于预防各种疾病的传播、提高人们的生活质量具有十分重要的意义。 Air purification and disinfection machine using the principle of high-pressure electrostatic field purification and disinfection and ultraviolet sterilization,through the body's touch screen,mobile phone applet or PC remote control of intelligent control mode,the air is purified while also multi-killing harmful substances such as various viruses,bacteria and other pathogens.The results show that the air purification and disinfection machine can realize the coexistence of man and machine,and has the advantages of mobility,intelligent control,safety and reliability,large purification amount,high purification and disinfection rate,and short required time.It is of great significance to prevent the spread of various diseases and improve people's quality of life.
作者 王高峰 WANG Gao-feng(Shangfeng Technology Co.,Ltd.,Taiyuan 030000,China)
出处 《机械工程与自动化》 2023年第3期202-204,共3页 Mechanical Engineering & Automation
关键词 空气净化消毒机 高压静电场 紫外线 air purification and disinfection machine high-pressure electrostatic field ultraviolet
  • 相关文献

参考文献4

二级参考文献36

  • 1张博,王明连,耿彦生,张青,王庆亮.我国空气净化消毒方法研究进展[J].环境与健康杂志,2007,24(9):745-747. 被引量:11
  • 2周凤平,吴熙凤,陈淑萍,徐若竹,肖全华,温济全,高永波.应用两种空气消毒方法对口腔种植手术室空气消毒效果比较[J].中国口腔种植学杂志,2009,14(1):16-18. 被引量:5
  • 3匡跃辉.环境污染热点问题初探[J].中国人口·资源与环境,2000,10(S1):44-46. 被引量:16
  • 4陈贵秋,朱应凯,李世康,黄威,高琼.床单位空气两用消毒机消毒效果试验观察[J].中国消毒学杂志,2006,23(1):40-42. 被引量:5
  • 5.消毒技术规范[S].[S].中华人民共和国卫生部,2002,11..
  • 6Marya CM,Shulda P, Dahiya V,et al. Current status of disinfection of dental impressions in Indian dental coUeges:a cause of concern [J]. J Infect Dev Cities,2011,5(11 ) :776-780.
  • 7Podg6rska M, Jakimiak B,Rohm-Rodowald E,et al. Assessment of disinfection and sterilization processes in dental practice as an impor- tant factors in prevention of infections [J]. Pizegl Epidemio1,2009,63 (4) :545-550.
  • 8Luksamijarulkul P,Panya N,Sujirarat D,et 81. Microbial air quality and standard precaution practice in a hoepital dental clinic [J]. J MedAssoc Thai ,2009,92(Suppl 7) :S148-S155.
  • 9Pasquarella C ,Veronesi L, Castiglia P,et al. Italian multicentre study on microbial environmenal contamination in dental clinics:a pilot study [J]. Sci Total Environ ,2010,408(19) :4045-4051.
  • 10Shivakumar KM ,Prashant GM ,Madhu Shankari GS,et al. Assessment of atmospheric microbial contamination in a mobile dental unit [J]. Indian J Dent Res ,2007,18(4) : 177-180.

共引文献15

同被引文献3

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部