期刊文献+

新能源并网变流器不平衡电网电压观测方法

Unbalanced Grid Voltage Observation Method for New Energy Grid-connected Converter
下载PDF
导出
摘要 常规基于二阶广义积分器的并网变流器电网电压观测方法不能实现不平衡电网电压观测,且受直流偏置影响。为此,提出了一种基于三阶广义积分器的并网变流器不平衡电网电压观测方法。此处首先介绍了基于二阶广义积分器的电网电压观测方法,并分析了直流偏置的影响。然后分析了三阶广义积分器可抑制直流偏置的优点,并提出了基于三阶广义积分器的电网电压基波分量、正交分量和电网电流微分信号观测方法。在此基础上,提出了一种基于三阶广义积分器的不平衡电网电压观测方法,消除了直流偏置的影响。实验研究验证了所提方法的有效性。 The conventional grid voltage observation method for grid-connected converter based on second-order generalized integrator cannot realize unbalanced grid voltage observation and it is affected by DC-bias.So,an unbalanced grid voltage observation method for grid-connected converter based on third-order generalized integrator is proposed.The grid voltage observation method based on second-order generalized integrator is introduced firstly,and the influences of DC-bias are analyzed.Then,the advantages of the third-order generalized integrator that can suppress DCbias are analyzed,and the observation method of the fundamental and the orthogonal components of grid voltage,as well as the differential signal of grid current,is proposed based on third-order generalized integrator.On this basis,an unbalanced grid voltage observation method based on third-order generalized integrator is proposed,which eliminates the DC-bias effects.Experimental studies verify the effectiveness of the proposed method.
作者 刘黎 俞恩科 俎立峰 滕林阳 LIU Li;YU En-ke;ZU Li-feng;TENG Lin-yang(State Grid Zhejiang Electric Power Co.,Ltd.Zhoushan Power Supply Company,Zhoushan 316000,China;不详)
出处 《电力电子技术》 北大核心 2023年第5期76-79,共4页 Power Electronics
基金 国网浙江省电力有限公司科技项目(5211ZS21-N001) 河南省重大科技专项项目(221100240500)。
关键词 二阶广义积分器 不平衡电网电压观测 三阶广义积分器 second-order generalized integrator unbalanced grid voltage observation third-order generalized integrator
  • 相关文献

参考文献5

二级参考文献50

  • 1赵仁德,贺益康.无电网电压传感器三相PWM整流器虚拟电网磁链定向矢量控制研究[J].中国电机工程学报,2005,25(20):56-61. 被引量:83
  • 2王久和,杨微,李华德.功率前馈电压型PWM整流器直接功率解耦控制[J].辽宁工程技术大学学报(自然科学版),2007,26(2):238-241. 被引量:19
  • 3Malinowski M, Kazmierkowski M P, Hansen S, et al.Virtu-M-flux-based Direct Power Control of Three-phase PWM Rectifiers[J].IEEE Trans. on Industry Applications,2001, 37(4) : 1019-1027.
  • 4Malinowski M, Jasinski M, Kazmierkowski M P.Simple Direct Power Control of Three-phase PWM Rectifier Us- ing Space-vector Modulation[J].IEEE Trans. on Industrial Electronics, 2004,51 ( 2 ) : 447-454.
  • 5Bon-Gwan Gu, Kwanghee Nam.A DC link Capacitor Min- imization Method Through Direct Capacitor Current Con- trol[J].IEEE Trans. on Industry Applications, 2006,42 (2) : 573-581.
  • 6Mohammadpour A, Sedeghi S, Parsa L. A generalized fanlt-tolerant control strategy for five-phase PM motor drives considering star, pentagon,and pentacle connections of stator windings [ J ]. IEEE Transactions on Industrial Electronics,2014,61 (1) : 63 -75.
  • 7O Wallmark, L Harnefom, O Carlson. Control algorithms for a fanh- tolerant PMSM drive [ J ]. IEEE Transactions on Industrial Elec- tronics,2007,54(4) :1973 - 1980.
  • 8F Aghili. Fanlt-tolerant torque control of BLDC motors [ J ]. IEEE Transactions on Industrial Electronics,2011,26 (2) :355 - 363.
  • 9W Zhan, M Chen8, W Hua,et al. Back-EMF harmonic analysis and fanh-tolerant control of flux-switching permanent-magnet machine with redundancy[ J]. IEEE Transactions on Industrial Electronics, 2011,58(5) :1926 - 1935.
  • 10LIU X Q, ZHANG H Y, LIU J, et al. Fault detection and diagnosis of permanent-magnet DC motor based on parameter estimation and neural network [J]. IEEE Transactions on Industrial Electronics, 2000,47 (5) : 1021 - 1030.

共引文献38

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部