摘要
以某LNG接收站IFV气化器主体工艺流程为例,综合分析了IFV气化器运行过程中可能出现的事故工况,详细阐述了各事故工况下的安全泄放量的计算方法和依据,可为后续IFV气化器的工程设计提供借鉴和参考。
Taking the main process flow of intermediate fluid vaporizer in a LNG terminal as an example,this paper comprehensively analyzes the accident conditions that may occur during the operation of intermediate fluid vaporizer,and expounds the calculation method and basis of safety relief capacity under each accident condition in detail,which can provide reference for the subsequent engineering design of intermediate fluid vaporizer.
作者
吴桂良
Wu Guiliang(CNOOC Petrochemical Engineering Co.,Ltd.,Jinan 250101,China)
出处
《山东化工》
CAS
2023年第10期241-243,共3页
Shandong Chemical Industry
关键词
LNG接收站
IFV气化器
事故工况
安全泄放量
LNG terminal
intermediate fluid vaporizer
accident conditions
safety relief capacity