期刊文献+

Study on failure mechanism of room and pillar with different shapes and configurations under uniaxial test and numerical simulation compression using experimental test and numerical simulation

原文传递
导出
摘要 Experimental and discrete element methods were used to investigate the failure behavior of room and pillar with different configura-tions under uniaxial loading.Concrete samples with dimension of 15 cm×15 cm×5 cm were prepared.Within the specimens,rooms and pillars with different configurations were provided.The room dimension was 1 cm×1 cm,and the pillar dimension was according to the room configuration.Twelve different configurations were chosen for rooms and pillars.The axial load was applied to the model by rate of 0.05 mm/min.The results show that the failure process was mostly governed by both the non-persistent joint angle and joint number.The compressive strength of the specimens was related to the fracture pattern and failure mechanism of the pillars.It was shown that the shear behaviour of pillars was related to the number of the induced tensile cracks,which increased by increasing the room angle.The compressive strength of samples increased with the increase of the room angle.The failure pattern and failure strength are similar in both methods,i.e.,the experimental testing and the numerical simulation.
出处 《Underground Space》 SCIE EI CSCD 2023年第2期105-121,共17页 地下空间(英文)
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部