摘要
为对比狂犬病荧光抗体病毒中和试验(FAVN)和单克隆抗体竞争酶联免疫吸附试验(ELISA)检测方法的相关性,用2种血清抗体检测方法分别检测在深圳市收集的798份宠物犬血清样品,利用McNemar检验和Kappa一致性检验对比研究2种方法的检测结果。结果显示:以FAVN方法检测结果为标准,单克隆抗体竞争ELISA方法的符合率为96.7%(95%CI:95.3%~97.8%),敏感性为97.6%(95%CI:96.2%~98.5%),特异性为84.9%(95%CI:72.9%~92.7%),约登指数为0.825。经McNemar检验,2种血清抗体检测方法的检测结果差异不具有统计学意义(P=0.078>0.05);经Kappa一致性检验,2种血清抗体检测方法检测结果不一致是小概率事件(P<0.001),且两者的检测结果一致性高(Kappa系数=0.758)。结果表明,用单克隆抗体竞争ELISA方法代替FAVN用于犬狂犬病病毒免疫抗体的大规模监测具有一定的可行性。
Atotal of 798 pet dog serum samples collected in Shenzhen were detected by fluorescent antibody virus neutralization test(FAVN)and monoclonal antibody competitive enzyme-linked immunosorbent assay(ELISA)for comparison of the two methods by McNemar test and Kappa consistency test.The results showed that,taking the FAVN test results as the standard,ELISA test results were 96.7%(95%CI:95.3%-97.8%)coincident,with the sensitivity of 97.6%(95%CI:96.2%-98.5%),specificity of 84.9%(95%CI:72.9%-92.7%),and Jordan index of 0.825.McNemar Test results revealed that,no significant difference(P=0.078>0.05)was observed from the results of the two methods.Kappa consistency test revealed that the inconsistent results of the two methods were determined as a small probability(P<0.001),instead,a high consistency(Kappa coefficient=0.758)was observed.In conclusion,FAVN could be replaced by monoclonal antibody competition ELISA that might be used for intensive monitoring for canine rabies immune antibodies.
作者
刘荣启
车军
罗国强
钟剑锋
林博文
Liu Rongqi;Che Jun;Luo Guoqiang;Zhong Jianfeng;Lin Bowen(Shenzhen Animal Disease Prevention and Control Center,Shenzhen,Guangdong 518000,China)
出处
《中国动物检疫》
CAS
2023年第6期102-106,共5页
China Animal Health Inspection