期刊文献+

HXD3C型机车列车供电柜试验时跳主断故障原因分析及处理

Analysis and treatment of main breaker tripping fault in head-end power cabinet during thetestof HXD3C locomotive
原文传递
导出
摘要 HXD3C型机车通过列车供电柜向旅客列车车辆提供DC600 V电源,为了验证该装置的性能,在机车出厂前需要利用地面负载进行试验,对出厂例行试验过程中出现的TCMS报列车供电柜故障并跳主断问题进行分析,并提出切实有效的解决措施。 The HXD3C locomotive provides DC600 V power to passenger vehicles through the head-end power cabinet.In order to verify the performance of this device,it is necessary to conduct a test using ground load before the locomotive delivery.The paper analyzes the head-end power cabinet faults and main circuit breaker tripping reported by TCMS during the routine test,and proposes the practical and effective solutions.
作者 宋玉坤 SONG Yukun(Equipment Supervision Department of China Railway Shenyang Group Co.,Ltd.,Shenyang 110001,China)
出处 《铁道机车与动车》 2023年第5期39-41,I0002,共4页 Railway Locomotive and Motor Car
关键词 列车供电柜 CMD TCMS 跳主断 head-end power cabinet CMD TCMS main breaker tripping