摘要 为研究预制混凝土外墙保温板系统的连接安全性,开展了保温板与抹面砂浆、混凝土的拉伸黏结强度试验,并进行了不同锚固件(HY-80、HY-60和HY-40)反向拉拔力和变形特性研究。结果表明:乳液型界面剂可有效改善聚合物砂浆与保温板的相容性,相应界面黏结强度提升了约85%;保温板采用钢丝网构造加强措施有利于提高保温板与混凝土的界面黏结强度;HY-80和HY-60与HY-40不锈钢锚固件相比,其反向拉拔力分别提高了32.8%和20.0%,可有效提升预制混凝土外墙保温板系统的连接性能。 In order to study the structural connection safety of the prefabricated concrete external wall insulation panel system,the tensile bond strength tests of the insulation panel surface mortar and concrete were carried out,and the reverse pull-out capacity and deformation characteristics of the anchors(HY-80,HY-60,HY-40)were analyzed.The results show that lotion type interfacial agent can effectively improve the compatibility of polymer mortar and silicone insulation panel,and the interfacial bonding strength is increased by 85%.At the same time,the insulation panel strengthened by steel mesh structure can improve of the bonding strength between the insulation panel and the concrete interface.Compared with HY-40 stainless steel anchors,using the HY-80 and HY-60 has 32.8%and 20.0%higher reverse pull-out force respectively,which can improve the connection performance of the prefabricated concrete external wall insulation panel system.
作者 陈宁 董庆广 王娟 CHEN Ning;DONG Qingguang;WANG Juan(Shanghai Research Institute of Building Sciences Co.,Ltd.,Shanghai 201100,China)
出处 《混凝土与水泥制品》 2023年第7期61-65,共5页 China Concrete and Cement Products
基金 “十四五”国家重点研发计划项目(2022YFC3801401-3) 上海市科委社发项目(22dZ1203102)。
关键词 预制混凝土外墙保温板 界面拉伸黏结强度 反向拉拔力 锚固件 保温板 Prefabricated concrete external wall insulation panel Tensile bond strength of interface Reverse pull-out capacity Anchor Insulation panel
  • 相关文献

参考文献7

二级参考文献105

共引文献126

同被引文献21

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部