期刊文献+

Numerical analysis and capacity evaluation of composite sprayed concrete lined tunnels 被引量:3

原文传递
导出
摘要 Spray-applied membranes for waterproofing of sprayed concrete tunnels have led to the possibility of shear transfer between primary and secondary linings through the membrane interface,with the potential for reducing overall lining thickness.Laboratory tests have shown a reasonable degree of composite action in beam specimens.In this study,a numerical model previously calibrated against such tests is applied to a whole tunnel,considering soil–structure interaction and staged lining construction.The model shows composite action,and load sharing between the lining layers is expected in the tunnel as in the beams.Parametric studies over the practical range of interface stiffness values show that composite action is maintained,although at high interface stiffness,excessive bending may be imposed on the secondary lining,requiring additional reinforcement.An effcient composite shell design with minimal additional rein-forcement is achievable if the secondary lining thickness is reduced as compared to current practice.Robustness of the system,measured in terms of the interface’s ability to transfer stress under unequal loading causing distortion on the tunnel,is found to be generally ade-quate.However,adjacent construction in close proximity may provide insuffcient margin on membrane tensile de-bonding,particularly if the membrane is partially or fully saturated.
出处 《Underground Space》 SCIE EI 2018年第2期87-108,共22页 地下空间(英文)
  • 相关文献

同被引文献13

引证文献3

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部