期刊文献+

核电站安全壳内乏燃料水池事故工况液位计国产化研发 被引量:1

Domestic Research of Level Gauge of Accident Conditions in Spent Fuel Pool in NPP Containment
下载PDF
导出
摘要 田湾核电站VVER堆型机组的乏燃料水池位于安全壳厂房,在严重事故工况下其运行环境极端恶劣,普通型乏燃料水池液位计无法保证对液位状态的可靠监测。由于现用的改进型电容式乏燃料水池液位计运行不稳定且原型仪表停产,田湾核电站基于导波雷达测量技术,研制了一种高可靠性的乏燃料水池液位计。该新型液位计采用分体式结构,配置专用的同轴电缆和独有的测量算法,攻克了分体仪表远距离信号传输、各类运行工况下的测量可靠性以及响应时间要求等研发难点,并且参考1E级电气设备鉴定等级要求完成了各类鉴定试验,满足严重事故工况下安全壳内乏燃料水池液位监测的设计要求,为核电站乏燃料水池液位监测仪表的选型与替代提供了一种国产化的产品。 The spent fuel pool of VVER reactor type units in Tianwan Nuclear Power Station is located in the containment building.Under severe accident conditions,its operating environment is extremely harsh,and the common spent fuel pool level gauge cannot ensure reliable monitoring of liquid level status.Due to the unstable operation of the existing modified capacitive spent fuel pool level gauge and the shutdown of the prototype instrument,Tianwan Nuclear Power Station developed a high reliability spent fuel pool level gauge based on guided wave radar measurement technology.The new type of level gauge adopts a split structure,is equipped with special coaxial cable and unique measurement algorithm,and overcomes research and development difficulties such as long-distance signal transmission of split instruments,measurement reliability under various operating conditions,and response time requirements.And various qualification tests were completed with reference to the requirements of Class 1E electrical equipment qualification level,meeting the design requirements for liquid level monitoring of the spent fuel pool in the containment under severe accident conditions.This provides a domestically produced product for the selection and replacement of liquid level monitoring instruments for the spent fuel pool in nuclear power plants.
作者 彭运美 董帅军 高飞洋 贺博 Peng Yunmei;Dong Shuaijun;Gao Feiyang;He Bo(Control and Instrument Office of Jiangsu Nuclear Power Corporation,Jiangsu,Lianyungang,222000,China)
出处 《仪器仪表用户》 2023年第8期57-61,共5页 Instrumentation
关键词 安全壳内乏燃料水池 事故工况 导波雷达液位计 国产化 spent fuel pool in containment accident condition guided wave radar localization
  • 相关文献

参考文献3

二级参考文献22

  • 1朱昊,李跃华,周亚凤.AD9501在精确测距系统中的应用[J].集成电路应用,2004,21(12):64-66. 被引量:3
  • 2[4]曹志刚,钱亚生.现代通信原理.北京:清华大学出版社.2000
  • 3[2]Digital visual interface DVI,version I.DDWG.1999.
  • 4GB/T12727-2002.核电厂安全系统电气设备质量鉴定[S].
  • 5EJ/T1197-2007.核电厂安全级电气设备质毓豁定试验方法与环境条件[s].
  • 6EJ/T609-1991.核电厂保护系统电气插件型式检验准则[S].
  • 7IEEE Std. 323. IEEE Standard for Qualifying Class 1E Equipment for Nuclear Power Generating Stations[S].
  • 8RCC—E-2005,压水堆核电站核岛电气设备设计和建造规则[s].
  • 9U. S. Code of Federal Regulations, Title 10, Part 50. Domestic Licensing of Production and Utilization Facilities. U. S. Nuclear Regulatory Commission, Washington, DC.
  • 10NUREG 0800, chapter 7. Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants: LWR Edition Instrumentation and Controls.