阐述了轧机主轴平衡系统发生泄漏和主轴平衡阀组出现失衡的故障现象,分析了故障产生的原因,提出了故障处理方法。总结了主轴平衡系统长寿命运行的先进操作法。
This article explains the leakage of the spindle balance system of the rolling mill and the imbalance of the spindle balance valve group,analyzes the causes of the faults,and proposes fault handling methods.It summarizes the advanced operating methods for the long service life operation of the spindle balance system.
作者
徐平
沈强
Xu Ping;Shen Qiang(Ansteel Education and Training Center;Hot-rolling Strip Mill of Angang Steel Co.,Ltd.,Anshan,Liaoning,114002)
出处
《冶金设备管理与维修》
2023年第3期50-52,共3页
Metallurgical Equipment Management and Maintenance
关键词
静压润滑
泄漏
主轴
轧机
Hydrostatic lubrication
leakage
spindle
rollingmill