摘要
建立了二氧化碳相变致裂装置加热剂的离子色谱分析方法。使用Dionex IonPac AS-19高容量阴离子分析柱可同时分析三种加热剂成分的阴离子,确定了3种阴离子和3种阳离子的保留时间,实现定性分析。对6种离子以峰面积Y对相应的质量浓度X(μg/mL)进行线性回归,绘制了标准曲线,并确定了相应的线性范围、检出限和定量限。方法灵敏度高,检出限低,稳定性好,可为公安机关在相应案件中对二氧化碳相变致裂装置中加热剂的检测提供依据。
The method was established for the analysis of CO_(2) phase change fracturing device heating agents by ion chromatography.A high-capacity Dionex IonPac AS-19 column was used for the simultaneous analysis of the three heater component anions and the retention times were determined for three anions and three cations.The linear regression of the peak area Y on the corresponding mass concentration X(μg/mL)for the six ions was performed,a standard curve was plotted and the corresponding linear ranges,the limits of detection,and the limits of quantification were determined.The method is sensitive,with low detection limits and good stability,and can provide a basis for the detection of heating agents in CO_(2) phase change fracturing devices by public security authorities in the corresponding cases.
作者
赵志东
孟娇
张显强
ZHAO Zhi-dong;MENG Jiao;ZHANG Xian-qiang(Guizhou Police College,Guiyang 550005,China;Guangzhou Institute of Chemistry,Chinese Academic of Science,Guangzhou 510650,China;University of Chinese Academic of Science,Beijing 100049,China)
出处
《广州化学》
CAS
2023年第3期73-74,77,共3页
Guangzhou Chemistry
基金
国家自然科学基金资助项目(42063002)
公安部技术研究计划(2020JSYJB07)
贵州省科技计划项目(黔科合支撑[2020]4Y059号)。
关键词
二氧化碳相变致裂
加热剂
离子色谱
分析
carbon dioxide phase change fracturing
heating agents
ionic chromatography
analysis