摘要
结合规范和安全检查的要求,对液化石油气供应站的紧急切断系统、烃泵和压缩机的传动方式、火灾延续时间取值进行分析,提出解决方案和建议。
Combined with the requirements of the specifications and the safety inspections,the emergency shutdown system,transmission modes of hydrocarbon pumps and compressors,and fire duration values of liquefied petroleum gas supply stations are analyzed,and solutions and suggestions are proposed.
作者
周春
张前
ZHOU Chun;ZHANG Qian
出处
《煤气与热力》
2023年第6期35-37,42,共4页
Gas & Heat
关键词
液化石油气供应站
紧急切断系统
传动方式
火灾延续时间
liquefied petroleum gas supply station
emergency shutdown system
transmission mode
fire duration