摘要
数据中心常用的供配电系统架构有2N系统、旁路模式、市电直供+UPS备份等,优化了系统架构,设计了新型的“异构”系统和新型的融合电力模块方案。“异构”系统和融合电力模块方案分别在金融行业和AI计算方面得到应用,可为同类项目提供参考。
Building a green and highly reliable data center power supply and distribution system,it commonly uses system architectures for power supply and distribution in data centers include 2N system,bypass mode,direct municipal power supply+UPS backup,etc.Through continuous optimization of the system architecture,new“heterogeneous”systems and new integrated power module solutions are designed.“Heterogeneous”systems and integrated power module solutions are applied in the financial industry and AI computing,respectively.Whether the two new technologies can be widely promoted still needs time to test.It can provide reference for similar project.
作者
任小佳
REN Xiaojia(Shanghai Architectural Design and Research Institute Co.,Ltd.,Shanghai 200041,China)
出处
《现代建筑电气》
2023年第5期27-32,共6页
Modern Architecture Electric
关键词
数据中心
2N配电架构
电力模块
可靠性
data center
2N distribution architecture
power module
reliability