从安全角度出发,对再气化模块的整体布置方案、火气系统、消防灭火系统和管道超压保护等方面的设计原则进行分析,提出相应设计要点,为浮式再气化装置(FSRU)以及再气化模块的设计优化和建造提供相关经验和指导意见。
From a safety perspective,the design principles of the overall layout plan,fire and gas system,fire extinguishing system,and pipeline overpressure protection of the regasification module are analyzed,and corresponding design points are proposed to provide relevant experience and guidance for the design optimization and construction of floating storage regasification unit(FSRU)and the regasification module.