为研究内置GFRP管多腔钢混凝土组合剪力墙的极限承载力,结合各组成材料的力学特性,考虑钢管与GFRP管对混凝土的约束作用,选取合适的本构模型,建立内置GFRP管多腔钢混凝土组合剪力墙的极限承载力计算公式。通过与已有试验和有限元分析结果进行对比,表明该公式能够较好地预测内置GFRP管多腔钢混凝土组合剪力墙的极限承载力。
To study the ultimate load⁃bearing capacity of the multicellular steel tube shear wall with FRP⁃confined concrete cores embedded in CFST columns as boundary elements,the ultimate load⁃bearing capacity formula is established by combining the mechanical characteristics of each material,considering the confining effect of steel tubes and GFRP tubes on concrete,and selecting suitable constitutive models.By comparing with the experimental results and simulated results,it shows that the formula can predict the ultimate load⁃bearing capacity of this composite shear wall better.
作者
赖楚麟
任凤鸣
田时雨
Lai Chulin;Ren Fengming;Tian Shiyu(Guangzhou University,Guangzhou 510006,China)
出处
《建筑科学》
CSCD
北大核心
2023年第5期76-83,96,共9页
Building Science
基金
国家自然科学基金(52178125、51878189)
广州市“羊城学者”科研项目(202032849)。
关键词
GFRP管
组合剪力墙
约束混凝土
极限承载力
GFRP tube
composite shear wall
confined concrete
ultimate bearing capacity