摘要
阐述励磁系统故障引发的发电厂电力系统事故发生过程,探讨发电公司Controgen HX型励磁调节器的两起整流柜导通故障处理经过,对其软硬件原理进行分析。
This paper describes the process of power system accident caused by excitation system fault in power plant,discusses the handling process of two rectifier cabinet conduction faults of Controlen HX excitation regulator in power generation company,and analyzes its software and hardware principles.
作者
刘志国
LIU Zhiguo(Sujin Shuozhou Gangue Power Generation Co.,Ltd.,Shanxi 036800,China)
出处
《集成电路应用》
2023年第6期182-183,共2页
Application of IC
关键词
励磁系统
电力系统事故
励磁调节器
整流柜
excitation system
power system accident
excitation regulator
rectifier cabinet