摘要
本文首先分析变压器空载合闸产生励磁涌流的原因,以及励磁涌流对电力系统造成的危害。为了有效降低变压器在空载合闸瞬间产生的励磁涌流,提高电力系统运行的可靠性,本文通过研究在变压器一次侧串电阻、并联变压器两种预充磁技术,并进行了对比仿真分析,结果表明预充磁变压器相更为有效的抑制励磁涌流。
This article first analyzes the reasons for the magnetizing inrush current caused by the no-load closing of the transformer,and the harm caused by the magnetizing inrush current to the power system.In order to reduce inrush current of the transformer at the moment of no-load closing,and improve the reliability of power system operation,this paper adopts simulation technology to analyze two kinds of pre-magnetization technology:resistor in series on the side of transformer and transformer in parallel,the results show that the pre-charged transformer can be more effective in suppressing the inrush current.
作者
关涛
袁鹏飞
冯国兵
许轶楠
Guan Tao;Yuan Pengfei;Feng Guobing;Xu Yinan(PLA Unit of 92942,Beijing 100161,China;Naval University of Engineering,Wuhan 430030,China)
出处
《船电技术》
2023年第7期89-92,共4页
Marine Electric & Electronic Engineering
关键词
变压器
预充磁技术
仿真
励磁涌流
technology of pre-magnetization
simulation
inrush current