摘要
本文通过研究漏电断路器分析短路分断产生的电弧问题。本文提出了电弧能量方程和电极时间关系因素,采用了高速数据采集系统来收集数据,并对电流分断过程中的电弧能量提供了解析。试验结果显示,合闸角度、短路电流、功率因数均会对漏电断路器电弧能量产生影响。
This paper analyzes the arc problem caused by short-circuit breaking by studying leakage circuit breakers.This paper proposes the arc energy equation and electrode time relationship factors,adopts a high-speed data acquisition system to collect data,and provides analysis of the arc energy during the current breaking process.The experimental results show that the closing angle,short-circuit current,and power factor all have an impact on the arc energy of the leakage current circuit breaker.
作者
陈天立
李纪凯
CHEN Tianli;LI Jikai(China Nuclear Power Engineering Co.,Ltd.Zhengzhou branch,Zhengzhou,Henan 450052,China)
出处
《自动化应用》
2023年第12期106-109,共4页
Automation Application
关键词
漏电断路器
电弧能量
短路分断
leakage circuit breaker
arc energy
short circuit breaking