期刊文献+

漏电断路器电弧能量影响因素的研究

Research on Arc Energy Influencing Factors of Leakage Circuit Breaker
下载PDF
导出
摘要 本文通过研究漏电断路器分析短路分断产生的电弧问题。本文提出了电弧能量方程和电极时间关系因素,采用了高速数据采集系统来收集数据,并对电流分断过程中的电弧能量提供了解析。试验结果显示,合闸角度、短路电流、功率因数均会对漏电断路器电弧能量产生影响。 This paper analyzes the arc problem caused by short-circuit breaking by studying leakage circuit breakers.This paper proposes the arc energy equation and electrode time relationship factors,adopts a high-speed data acquisition system to collect data,and provides analysis of the arc energy during the current breaking process.The experimental results show that the closing angle,short-circuit current,and power factor all have an impact on the arc energy of the leakage current circuit breaker.
作者 陈天立 李纪凯 CHEN Tianli;LI Jikai(China Nuclear Power Engineering Co.,Ltd.Zhengzhou branch,Zhengzhou,Henan 450052,China)
出处 《自动化应用》 2023年第12期106-109,共4页 Automation Application
关键词 漏电断路器 电弧能量 短路分断 leakage circuit breaker arc energy short circuit breaking