期刊文献+

磁敏感血管征在缺血性脑卒中的临床应用进展 被引量:1

Progress in clinical application of magnetic sensitive vascular sign in ischemic stroke
下载PDF
导出
摘要 缺血性脑卒中发病率高、复发率高,是造成我国居民残疾和死亡的主要原因之一。近年来,磁敏感加权成像上发现的磁敏感血管征越来越得到临床重视,其形成机制以及与脑卒中的关系已成为目前研究热点。现就磁敏感血管征的临床应用进行综述,旨在为缺血性脑卒中的诊疗提供更多的参考。 Ischemic stroke has a high incidence rate and recurrence rate,which is one of the main causes of disability and death of Chinese residents.In recent years,the magnetic sensitive vascular sign discovered on magnetic sensitive weighted imaging has received increasing clinical attention,and its formation mechanism and relationship with stroke have become current research hotspots.This article reviews the clinical application of magnetic sensitive vascular sign,aiming to provide more references for the diagnosis and treatment of ischemic stroke.
作者 谭洋(综述) 张良(综述) 王斌(审校) Tan Yang;Zhang Liang;Wang Bin(Department of Imaging,The Second Affiliated Hospital of Inner Mongolia University for Nationalities,Hulunbuir 021500,China)
出处 《疑难病杂志》 CAS 2023年第7期757-761,共5页 Chinese Journal of Difficult and Complicated Cases
关键词 缺血性脑卒中 磁敏感加权成像 磁敏感血管征 Susceptibility weighted imaging Susceptibility vessel sign Ischemic cerebral stroke
  • 相关文献

参考文献12

二级参考文献85

  • 1中华医学会神经病学分会脑血管病学组急性缺血性脑卒中诊治指南撰写组.中国急性缺血性脑卒中诊治指南2010[J].中国医学前沿杂志(电子版),2010,2(4):50-59. 被引量:1819
  • 2脑卒中患者临床神经功能缺损程度评分标准(1995)[J].中华神经科杂志,1996,29(6):381-383. 被引量:15726
  • 3Ogawa S, Lee TM,Nayak AS, et al. Oxygenation-sensitive contrast in magnetic resonance image of rodent brain at high magnetic fields. Magn Reson Med, 1990, 14(1): 68- 78.
  • 4Haacke EM, Cheng NY, House M J, et al. Imaging iron stores in the brain using magnetic resonance imaging. Magn Reson Imaging, 2005, 23(1): 1-25.
  • 5Li D, Waight D J, Wang Y. In vivo correlation between blood T2^* and oxygen saturation. J Magn Reson Imaging, 1998, 8(6): 1236-1239.
  • 6Thulborn KR, Waterton JC, Matthews PM, et al. Oxygenation dependence of the transverse relaxation time of water protons in whole blood at high field. Biochim Biophys Acta, 1982, 714(2): 265-270.
  • 7Reichenbach JR, Haacke EM. High-resolution BOLD venographic imaging: a window into brain function. NMR Biomed, 2001, 14(7-8): 453-467.
  • 8Reichenbach JR, Bartll M, Haacke EM, et al. High- resolution MR venography at 3.0 Tesla. J Comput Assist Tomogr, 2000, 24(6): 949-957.
  • 9Lin W, Mukherjee P, An H, et al. Improving high- resolution MR bold venographic imaging using a T1 reducing contrast agent. J Magn Reson Imaging, 1999, 10(2): 118-123.
  • 10Sedlacik J, Helm K, Rauscher A, et al. Investigations on the effect of caffeine on cerebral venous vessel contrast by using susceptibility-weighted imaging (SWI) at 1.5, 3 and 7 T. Neuroimage, 2008, 40(1 ): 11-18.

共引文献1216

同被引文献13

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部