摘要 主要介绍了一款硅二极管温度计以及其配套干、湿式低温测试系统,对其灵敏度、互换性、测温精度、重复性等进行实验,并拟合了标准特性曲线。结果表明:互换性温差低至±0.2 K@4 K;低温下灵敏度最高可达-38 mV/K;测温精度<12 mK@77 K;适合低温下的测温应用。 A silicon diode thermometer,equiped with dry and wet test system at low temperature,was mainly introduced.An experiment was carried out on the thermometer sensitivity,interchangeability,temperature measurement accuracy and repeatabili⁃ty,the standard characteristic curve was fitted.Results show that the deviation of interchangeability is less than 2 mK@4 K,the sensitivity at low temperature can reach up to-38 mV/K,the temperature measurement accuracy is less than 12 mK@77 K.The thermometer is suitable for temperature measurement applications in low temperature scenarios.
作者 李泽宇 蒋燕阳 张成俊 邵峰 邓伟峰 Li Zeyu;Jiang Yanyang;Zhang Chengjun;Shao Feng;Deng Weifeng(College of Energy,Soochow University,Suzhou 215000,China;Photon Technology(Zhejiang)Co.,Ltd.,Jiaxing 314000,China)
出处 《低温与超导》 CAS 北大核心 2023年第6期77-83,共7页 Cryogenics and Superconductivity
基金 江苏省高等学校自然基金(21KJB470012) “量子安全通信和数据透明加密技术研究及应用-高性能超导纳米线单光子探测系统研发及产业化”项目(2021C01188)资助。
关键词 低温温度计 硅二极管 低温测量 低温系统 Cryogenic thermometer Silicon diode Cryogenic measurement cryogenic System
  • 相关文献

参考文献5

二级参考文献12

  • 1王秋良.高磁场超导磁体科学[M].北京:科学出版社,2007.
  • 2叶海峰,等.150A高温超导电流引线设计与性能测试[J].真空与低温,2011(增刊):232-239.
  • 3Yeon Suk Choi. Optimal cool-down time of a 4 K superconducting magnet cooled by a two-stage Cryocooler [ J]. Beijing: Cryogenics, 2012,52: 13-18.
  • 4张海峰,叶海峰,王福堂,等.零蒸发率低温超导磁体系统的设计与实验[C].第十一届全国低温工程大会会议论文集,2013:323-326.
  • 5Natarajan C M,Tanner M G,Hadfield R H. Superconducting nanowire single-photon detectors: physics and applications [J]. Superconductor Science and Technology ,2012,25 ( 6 ) :063001.
  • 6Hadfield R H. Single-photon detectors for optical quantum infi~rmation applications[ J ]. Nature Photonics,2009,3 ( 12 ) :696-705.
  • 7Eisaman M D, Fan J, Migdall A, et al. Invited rvicw aticle : single-pho- ton sources and detectors[J]. Review of Scientific Instruments,2011 , 82(7) :071101-1-071101-25.
  • 8hzler M A,Jiang X D, Entwistle M ,et al. Advances in gas-based ava- lanche diode single photon detectors [ J ]. Journal of Modern Optics, 2011,58(3-4) :174-200.
  • 9Radebaugh R. Refrigeration for superconductors [ J ]. P IEEE,2004, 92(10) :1719-1734.
  • 10汪汀,张萍萍,陈浩树.BESⅢ低温超导磁体线圈骨架及恒温容器的研制[J].舰船科学技术,2011,33(3):69-73. 被引量:4

共引文献27

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部