摘要 冷热源的自控系统管理建筑能耗的60%,是实现节能减排重要措施之一。冷热源的自控技术也是建筑设备监控系统当中最复杂、技术要求最高的部分,通常由多个控制器组网通信逻辑控制实现,对控制器之间的变量同步和编程能力要求较高。可信自控公司采用自研的BO控制器编程语言接近自然语言模式,简化实现复杂的系统的数据采集、过程控制、逻辑控制功能。 The automatic control system of cold and heat sources manages 60%of building energy consumption,which is one of the important measures to achieve energy conservation and emission reduction.The automatic control technology of cold and heat sources is also the most complex and technically demanding part of the building equipment monitoring system.It is usually realized by the networking communication logic control of multiple controllers,which requires high variable synchronization and programming ability between controllers.Kexin Controls Corporation adopts the self-developed BO controller programming language close to the natural language mode,which simplifies the realization of complex system data acquisition,process control and logiccontrol functions.
作者 卞立群 Bian Liqun(Shenzhen Kexin Controls Corporation,Shenzhen 51800,China)
出处 《绿色建造与智能建筑》 2023年第7期35-39,共5页 GREEN CONSTRUCTION AND INTELLIGENT BUILDING
关键词 冷热源自控系统 建筑设备监控系统(BAS) 节能减排 双碳目标 automatic control system of cold and heat sources Building Automation System(BAS) energy conservation and emissionreduction doublecarbontargets