摘要 为了研究重庆地区住宅室内各季节真菌气溶胶的浓度分布和影响因素,在该地选取23户住宅进行了室内外真菌气溶胶浓度检测和温湿度测量。结果表明:在测试期间,夏季、过渡季和冬季室内真菌气溶胶浓度平均值分别为1655.8、1412.8、465.9 cfu/m 3,夏季和过渡季的浓度显著高于冬季;室内真菌气溶胶的峰值粒径、中值粒径均处于第四级(2.10μm,3.30μm),冬季第四级粒径占比最大,中值粒径最小;室内真菌气溶胶浓度与室外浓度、室内温度和相对湿度均呈显著正相关(显著性水平P<0.01),Spearman相关系数分别为0.799、0.533和0.574;全年室内外真菌气溶胶浓度之比(I/O值)平均为1.25,说明室内源>室外源。 In order to study the distribution and influencing factors of fungal aerosol concentration in residential buildings in Chongqing in different seasons,23 residences are selected for indoor and outdoor fungal aerosol concentration detection and temperature and humidity measurement.The results show that during the test period,the average indoor fungal aerosol concentrations in summer,transition season and winter are 1655.8,1412.8,465.9 cfu/m 3,respectively.The concentrations in summer and transition season are significantly higher than that in winter.The peak and count median diameters of indoor fungal aerosol are in the fourth level(2.10μm,3.30μm),the fourth level particle size accounts for the largest proportion and the count median diameter is the smallest in winter.Indoor fungal aerosol concentration is significantly positively correlated with outdoor concentration,indoor temperature and relative humidity,the significance level P is less than 0.01,and the Spearman correlation coefficients are 0.799,0.533 and 0.574,respectively.The average annual I/O ratio is 1.25,which shows that the concentration of indoor sources is higher than that of outdoor sources.
作者 郭芯竹 杜晨秋 喻伟 王玉珏 杨婷 路冰洁 Guo Xinzhu;Du Chenqiu;Yu Wei;Wang Yujue;Yang Ting;Lu Bingjie(Chongqing University,Chongqing)
机构地区 重庆大学
出处 《暖通空调》 2023年第8期85-91,共7页 Heating Ventilating & Air Conditioning
基金 国家青年科学基金项目“室内空气湿度对儿童过敏性哮喘发病的影响及其机理”(编号:51908079)。
关键词 真菌气溶胶 浓度分布 影响因素 粒径分布 室内空气品质 微生物污染 相关性分析 fungal aerosol concentration distribution influencing factor particle size distribution indoor air quality microbial contamination correlation analysis
  • 相关文献

参考文献8

二级参考文献180

  • 1莫秀娟.居室装修后空气中甲醛、三苯释放规律及防治对策[J].干旱环境监测,2004,18(3):132-134. 被引量:8
  • 2王红玉,陈育智,马煜,黄永坚,赖奇伟,钟南山.中国儿童哮喘患病率的地区差异与生活方式的不同有关[J].中华儿科杂志,2006,44(1):41-45. 被引量:37
  • 3Dassonville C,Demattei C,Detaint B,et al. Assessment andpredictors determination of indoor airborne fungal concentrationsin Paris newborn babie,s homes [ J ]. Environmental Research,2008,108(1) :80-85.
  • 4Li H L,Shan N. Investigation on the status of microbialcontamination in air conditioner system [ J]. Shanghai Journal ofPreventive Medicine,2004,16(3) ; 138-138,141.
  • 5Shen J M,Xu Z L. Secondary contamination and bacterial controlin air conditioning systems [ J ]. Heating Ventilating & AirConditioning,2002,32(5) :5-8.
  • 6Miller J D. Fungi as contaminants in indoor air[ J] . AtmosphericEnvironment,1992,26(12) :2163-2172.
  • 7Horner W E ,Helbling A,Salvaggio J E ,et al. Fungal allergens[J]. Clinical Microbiology Reviews,1995 ,8(2) :161-179.
  • 8Douwesi J,Thorne P,Pearce N,et al. Bioaerosol health effectsand exposure assessment :progress and prospects [ J ]. TheAnnals of Occupational Hygiene,2003,47(3) :187-200.
  • 9Koster J A D,Thorne P S. Bioaerosol concentrations innoncomplaint,complaint,and intervention homes in the Midwest[J ]. American Industrial Hygienic Association Journal,1995 ,56:573-580.
  • 10Kodama A M,Mcgee R I. Airborne microbial contaminants inindoor environments. Naturally ventilated and air-conditionedhomes[ J]. Archives of Environmental Health,1986,41(5):306-311.