摘要
本文对直流稳压电源使用中发生输入断电再接通,电源未正常启动问题的原因进行了定位,对问题产生的机理进行了分析,提出了问题解决措施,并通过实验验证了解决措施的有效性。
In this paper,the causes of the problem that the DC regulated power supply is not started when the input power is cut off and then turned on are located,the mechanism of the problem is analyzed,and the problem solving measures are proposed,and the effectiveness of the solutions is verified through experiments.
作者
申宏伟
张昊东
万志华
曹帅
SHEN Hong-wei;ZHANG Hao-dong;WAN Zhi-hua;CAO Shuai(Beijing Institute of Space Launch Technology,Beijing 10076,china)
出处
《移动电源与车辆》
2023年第2期55-57,共3页
Movable Power Station & Vehicle
关键词
直流稳压电源
启动异常
问题分析
DC regulated power supply
abnormal startup
problem analysis