某电厂EDI装置产水流量下降原因分析及处理

Cause Analysis and Treatment of Water Production Flow Decline of EDI Unit in a Power Plant
下载PDF
导出
摘要 某电厂EDI装置在给水泵入口压力提高和维持不变的情况下,EDI产水母管流量呈明显下降趋势。经排查EDI装置入口水质存在波动,化验出二级反渗透入口所加的氢氧化钠纯度不符合标准要求,同时分析出EDI装置入口水质含有微量氧化性物质,其逐步氧化降解EDI树脂,进而影响EDI产水流量。 Under the condition that the inlet pressure of the feedwater pump is increased and maintained in the EDI device of a power plant,the flow rate of the meduse-producing tube decreases obviously.After checking the fluctuation of water quality at the entrance of EDI device,it was found that the purity of sodium hydroxide added at the secondary reverse osmosis entrance did not meet the standard requirements.At the same time,it was analyzed that the water quality at the entrance of EDI device contained trace oxidizing substances,which gradually oxidized and degraded EDI resin,thus affecting the EDI discharge water flow.
作者 伏文 周洋 刘松松 吕馥丞 FU Wen;ZHOU Yang;LIU Song-song;LYU Fu-cheng(Shandong Huanfa Ruiqing Environmental Co.,Ltd.,Ji’nan 250100,China;Shandong Branch of Huadian Electric Power Research Institute Co.,Ltd.,Ji’nan 250002,China;Huadian Zibo Thermoelectric Co.,Ltd.,Zibo 255054,China;Huadian Qingdao Power Generation Co.,Ltd.,Qingdao 266031,China)
出处 《化工管理》 2023年第22期112-116,共5页 Chemical Engineering Management
关键词 EDI装置 氧化性物质 降解 树脂 EDI device oxidizing substance degradation resin