摘要 柔性接头作为深水钢悬链立管(SCR)的关键部件,在海洋服役环境中承受着巨大载荷及面临着介质酸化导致的断裂风险等问题。因此,本研究针对钢悬链立管用ASTM A707 L5材料开展力学性能、氢致开裂(HIC)、应力腐蚀开裂(SSC)及裂纹顶端张开位移(CTOD)试验研究。试验结果表明,采用ASTM A707 L5钢制成的柔性接头其力学性、HIC、SSC及CTOD试验性能均能满足规格书要求;经HIC试验后试样的裂纹长度率(CLR)、裂纹厚度率(CTR)及裂纹敏感率(CSR)均为0;SSC试验后试样均为发生断裂,在10倍显微镜下观察,所有试样表面均未发现裂纹;CTOD的最小值为1.0792,平均值为1.1534. As a key component of deep water flexible Joint of steel catenary riser(SCR),flexible joints are subjected to huge loads in the marine service environment and face the fracture risk caused by medium acidification.Therefore,the mechanical properties,hydrogen induced cracking(HIC),stress corrosion cracking(SSC)and crack tip opening displacement(CTOD)of ASTM A707L 5 for flexible Joint of steel catenary riser were studied.The test results show that the mechanical properties,HIC,SSC and CTOD test properties of the flexible joint made of ASTM A707 L5 Steel can meet the requirements of the specification;The crack length ratio(CLR),crack thickness ratio(CTR)and crack sensitivity(CSR)of the specimens were all 0 after HIC test.After SSC test,all the samples were broken,and no cracks were found on the surface of all samples under 10 times microscope,the minimum value of CTOD was 1.0792,and the average value was 1.1534.SSC Test is an effective method for the determination of CTOD.
作者 杜卫锋 李华军 富锐 管鑫 高光军 吕永超 DU Wei-Feng;LI Hua-Jun;FU Rui;GUAN Xin;GAO Guang-Jun;LV Yong-Chao(Xi'an Sunward Aerospace Material Co.,Ltd.,Xi'an Shannxi710025,China;China Productivity Center For Machinery Co.,Ltd.,Beijing100044,China)
出处 《机电产品开发与创新》 2023年第4期159-161,共3页 Development & Innovation of Machinery & Electrical Products
关键词 钢悬链立管柔性接头 ASTM A707 L5 HIC SSC CTOD Flexible Joint of steel catenary riser ASTM A707 L5 HIC SSC CTOD
  • 相关文献

参考文献4

二级参考文献21

  • 1孟庆飞,黄维平,刘建军.深水钢悬链式立管与浮式平台整体分析方法研究[J].振动与冲击,2013,32(17):19-23. 被引量:4
  • 2陈蕾,谈峰,戴娟.数控机床的发展趋势[J].机械设计与制造,2005(9):175-176. 被引量:8
  • 3王伟.数控机床液压系统引发的故障及诊断技术[J].液压与气动,2006,30(9):78-80. 被引量:7
  • 4杨才福,张永权,刘天军.汽车用含铜高强度薄钢板[J].钢铁研究学报,1997,9(3):63-66. 被引量:8
  • 5Banadkouki S S,Yu D,Dunne D P.Age Hardening in a Cu-Bearing High Strength Low Alloying Steel [J].ISIJ Interna-tional,1996,36(1):61-67.
  • 6Thompson S W,Krauss G.Copper Precipitation during Con-tinuous Cooling and Isothermal Aging of A710-Type Steels[J].Metallurgical and Materials Transactions,1996,27A(6):1573-1588.
  • 7Gionata Carmignani. An integrated structu-ral framework to cost-based FMECA:The priority-cost FMECA[J].Reliability Engineering and System Safety,2009,(94):861-871.
  • 8孙志礼;张义民.数控机床性能分析及可靠性设计技术[M]北京:机械工业出版社,201136-47.
  • 9童时中;童和钦.维修性及其设计技术[M]北京:中国标准出版社,200575-82.
  • 10甘茂治;康建设;高崎.军用装备维修工程学[M]北京:国防工业出版社,200537-43.

共引文献20

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部