针对使用水冷柴油发电机的缺水工程,提出高温水回流和排放两种运行方式下发电机可运行时长的计算方法,描述温度和水量的变化过程。通过对两种方式的计算结果进行比较,可作为在相应条件下理论与实际运行过程的参考数据。
Aiming at the project lacking water installed water-cooled diesel generator,the calculation method of the operating time of the motor under two operating modes of high temperature water reflux and discharge is presented,and the changing process of temperature and quantity of water is described.After comparing the calculation results of the two methods,it can be used as reference data for theoretical and practical use process under corresponding conditions.
作者
马向伟
刘文波
都的箭
肖丽君
吴晴
Ma Xiangwei;Liu Wenbo;Du Dejian;Xiao Lijun;Wu Qing(The Chinese People’s Liberation Army 95899 Unit,Beijing 100068,China)
出处
《山西建筑》
2023年第17期137-138,172,共3页
Shanxi Architecture
关键词
缺水工程
水冷柴油发电机
运行时长
water lacking project
water-cooled diesel generator
operating time