期刊文献+

基于AHRI Standard 210/240-2023的挂壁式空调机测试要点解读

Interpretation on test points of wall-mounted air conditioner based on AHRI Standard 210/240-2023
下载PDF
导出
摘要 基于AHRI Standard 210/240-2023 Standard for Performance Rating of Unitary Air-conditioning&Air-source Heat Pump Equipment,对本标准的适用范围及挂壁式空调机的安装过程、测试方法、评价方式进行解读,分析室外焓差法,建议制造企业进行H4Full测试,为测试人员及制造企业正确理解新版标准及相关认证测试提供参考。 Based on AHRI Standard 210/240-2023 Standard for Performance Rating of Unitary Air-conditioning&Air-source Heat Pump Equipment,the application scope of this standard and the installation process,test method and evaluation method of the wall-mounted air conditioner are interpreted.The outdoor enthalpy difference method is analyzed and it is recommended that manufacturing enterprises carry out H4_(Full)testing,hoping to provide a reference for testers and manufacturing enterprises to correctly understand the new version of the standard and related certification tests.
作者 陈欣 顾成曦 杨弋 李芳 陈海 任道一 Chen Xin;Gu Chengxi;Yang Yi;Li Fang Chen;Hai Ren Daoyi(Hefei General Machinery ResearchInstitute Co.,Ltd.)
出处 《制冷与空调》 2023年第7期51-54,90,共5页 Refrigeration and Air-Conditioning
关键词 空调 热泵 空气源 焓差法 air-conditioning heat pump air-source enthalpy difference method
  • 相关文献

参考文献3

二级参考文献10

共引文献21

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部