摘要
基于AHRI Standard 210/240-2023 Standard for Performance Rating of Unitary Air-conditioning&Air-source Heat Pump Equipment,对本标准的适用范围及挂壁式空调机的安装过程、测试方法、评价方式进行解读,分析室外焓差法,建议制造企业进行H4Full测试,为测试人员及制造企业正确理解新版标准及相关认证测试提供参考。
Based on AHRI Standard 210/240-2023 Standard for Performance Rating of Unitary Air-conditioning&Air-source Heat Pump Equipment,the application scope of this standard and the installation process,test method and evaluation method of the wall-mounted air conditioner are interpreted.The outdoor enthalpy difference method is analyzed and it is recommended that manufacturing enterprises carry out H4_(Full)testing,hoping to provide a reference for testers and manufacturing enterprises to correctly understand the new version of the standard and related certification tests.
作者
陈欣
顾成曦
杨弋
李芳
陈海
任道一
Chen Xin;Gu Chengxi;Yang Yi;Li Fang Chen;Hai Ren Daoyi(Hefei General Machinery ResearchInstitute Co.,Ltd.)
出处
《制冷与空调》
2023年第7期51-54,90,共5页
Refrigeration and Air-Conditioning
关键词
空调
热泵
空气源
焓差法
air-conditioning
heat pump
air-source