摘要
结合防水通用规范要求,以地下室底板部位为例,对通常采用的预铺反粘防水做法进行了探讨,防水一级设防推荐采用1.5 mm厚自粘防水卷材+1.5 mm厚预铺TPO高分子防水卷材,并介绍了具体的防水施工工艺以及细部节点做法。
Based on the“General code for waterproofing of building and municipal engineering”and taking the basement floor as an example,the commonly used pre-laid reverse adhering waterproofing method is discussed in this article.It is recommended to use 1.5 mm thick self-adhesive waterproofing membrane+1.5 mm thick pre-laid TPO waterproofing membrane for gradeⅠwaterproofing protection,and specific waterproofing construction technology and detail treatment methods are introduced as well.
作者
赵东菊
孙荣喜
田令
Zhao Dongju;Sun Rongxi;Tian Ling(Keshun Waterproof Technology Co.,Ltd.,Foshan,Guangdong 528200,China)
出处
《中国建筑防水》
2023年第8期31-34,共4页
China Building Waterproofing
关键词
防水通用规范
地下室底板
一级设防
预铺反粘法
自粘防水卷材
预铺TPO高分子防水卷材
general code for waterproofing of building and municipal engineering
basement floor
grade玉protection
prelaid reverse adhering method
self-adhesive waterproofing membrane
pre-laid TPO waterproofing membrane