期刊文献+

基于碱性过硫酸钾干燥箱中消解水样测定总氮的条件探讨

Discussion on the Conditions of Determination of Total Nitrogen Based on Digestion of Water Samples in Alkaline Potassium Persulfate Drying Oven
下载PDF
导出
摘要 基于HJ636-2012水质总氮测定中高压灭菌器消解存在的问题,通过对消解温度、时间、消解器、干扰情况等分析,说明用电热恒温干燥箱在125℃恒温40 min,自然退至室温,替代环境监测标准要求的高压灭菌器进行批量水质消解,该方法可以在水质总氮监测中推广应用。 Based on the problems of autoclave digestion in HJ636-2012 determination of total nitrogen in water quality,this paper analyzes the digestion temperature,time,digester and interference,and shows that the electrothermal constant-temperature drying oven is kept at 125℃for 40 min,and naturally returns to room temperature to replace the autoclave required by environmental monitoring standards for batch water quality digestion.This method can be popularized and applied in water quality total nitrogen monitoring.
作者 邬学清 郭振明 李燕中 金宏 WU Xue-qing;GUO Zheng-ming;LI Yan-zhong;JIN Hong(School of Chemistry&Chemical Engineering,Jining Normal University;Institute of Agriculture and Forestry Sciences Office of Ulanqab,Ulanqab,Inner Mongolia,012000)
出处 《集宁师范学院学报》 2023年第3期45-49,共5页 Journal of Jining Normal University
基金 集宁师范学院科研项目“水质总氮、总磷测定的方法验证及应用”(jsky2021018)。
关键词 水质 总氮 恒温 消解 测定 water quality total nitrogen constant temperature digestion determination
  • 相关文献

参考文献8

二级参考文献59

共引文献19

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部