期刊文献+

台式液体折射率测定仪量值溯源方法的研究 被引量:1

Research on traceability method for Bench-top LiquidRefractometers
原文传递
导出
摘要 选用有证标准物质和特定的温度测量装置组成标准器组,并论证了标准器组选用的科学性,克服了长期以来对准确获取台式液体折射仪样品表面温度的难题。依据台式液体折射率测定仪的工作原理制定评估该类仪器计量性能的测量模型,并对广泛流通的7个品牌、8种型号的台式液体折射仪的计量性能做系统进行评估,结合实验结果和测量不确定度评定结果拟定了可参考的计量特性指标,为建立此类仪器的量值溯源链提供了研究基础。 In this research,certified reference materials and specific temperature measuring devices are selected to form the standard group,and the scientific nature of the standard group selection is demonstrated,which overcomes the long-term problem of accurately obtaining the surface temperature of the table type liquid refractometer sample.According to the working principle of the Bench-top Liquid Refractometers,the measurement model for evaluating the metrological performance of such instruments is developed,and the metrological performance of the widely circulated Bench-top Liquid Refractometers of 7 brands and 8 models is systematically evaluated.Combined with the test results and the measurement uncertainty evaluation results,the referential metrological characteristic indicators are developed,which provides a research basis for establishing the traceability chain of the measurement value of such instruments.
作者 黄翊 范晓辉 何日梅 韦秋叶 卢敏萍 HHANG Yi;FAN Xiaohui;HE Rimei;WEI Qiuye;LU Minping(GuangxiZhuang Autonomous Region Institute of Metrology&Test,Nanning 530007,China)
出处 《自动化与仪器仪表》 2023年第7期278-282,共5页 Automation & Instrumentation
基金 广西重点研发计划项目(桂科AB21220050)。
关键词 台式液体折射率测定仪 量值溯源 不确定度 校准 Bench-top liquid refractometers traceability uncertainty calibration
  • 相关文献

参考文献9

二级参考文献60

  • 1胡晓伟,倪旭翔,朱育军,徐进.基于CMOS图像传感器的液体折射率计研究[J].光学仪器,2005,27(4):69-72. 被引量:7
  • 2辛督强,朱民,解延雷,张涛.测量液体折射率的几种方法[J].大学物理,2007,26(1):34-37. 被引量:58
  • 3DMITRIEV D A,NIKONOROV N V,SALAHETDINOV I F.Diffraction method for determination of refractive index of liquid media[J].SPIE,1993,2108:153-161.
  • 4叶德培.一级注册计量师基础知识及专业实务[M].北京:中国计量出版社,2009.
  • 5王之江.光学技术手册[M].北京:机械工业出版社,1987..
  • 6费业泰.误差理论与数据处理[M].机械工业出版社,2001..
  • 7GB3101-1993有关量、单位和符号的一般原则[S].北京:中国标准出版社,1994
  • 8Nemoto S.Measuring of the refractive index of liquid us-ing laser beam displacement[J].Appl. Opt., 1992, 31:6690-6694.
  • 9费业态.误差理论与数据处理[M].北京:机械工业出版社,2004.
  • 10JJF1059-2012测量不确定度评定与表示[S].北京:中国质检出版社,2012.