期刊文献+

地埋式污水处理厂MBR工艺调试及运行研究 被引量:1

Research on MBR Process Debugging and Operation of Underground Sewage Treatment Plant
下载PDF
导出
摘要 膜生物反应器(MBR)工艺流程短,集成度与自动化程度高,产水水质良好,产水消毒后可直接回用,占地空间小,其广泛应用在地埋式污水处理厂的建设中。本文以兰州市盐场污水处理厂扩建工程为例,分析MBR工艺设计,总结地埋式污水处理厂MBR工艺调试经验。调试运行数据显示,出水化学需氧量(COD_(Cr))、五日生化需氧量(BOD_(5))、氨氮(NH_(3)-N)、总氮(TN)、总磷(TP)的平均值分别为24.00 mg/L、6.00 mg/L、1.53 mg/L、9.40 mg/L、0.16 mg/L,均显著优于《城镇污水处理厂污染物排放标准》(GB 18918—2002)的一级A标准,污水处理厂可稳定、可靠地运行。 Membrane bioreactor(MBR)has a short process flow,high integration and automation level,and the produced water has good water quality and can be directly reused after disinfection,it occupies a small space and is widely used in the construction of underground sewage treatment plants.Taking the expansion project of Lanzhou Yanchang Sewage Treatment Plant as an example,this paper analyzes the MBR process design and summarizes the experience of MBR process debugging of underground sewage treatment plants.The debugging and operation data show that the average values of effluent chemical oxygen demand(COD_(Cr)),five-day biochemical oxygen demand(BOD_(5)),ammonia nitrogen(NH_(3)-N),total nitrogen(TN)and total phosphorus(TP)are 24.00 mg/L,6.00 mg/L,1.53 mg/L,9.40 mg/L and 0.16 mg/L respectively,which are significantly better than the ClassⅠA standard in the"Discharge Standard of Pollutants for Municipal Sewage Treatment Plants"(GB 18918—2002),and the sewage treatment plant can operate stably and reliably.
作者 冯天喜 王雷 张涛锋 雷声 黎小龙 袁正军 FENG Tianxi;WANG Lei;ZHANG Taofeng;LEI Sheng;LI Xiaolong;YUAN Zhengjun(China Railway Water Group Co.,Ltd.,Xi'an 710018,China)
出处 《中国资源综合利用》 2023年第8期193-198,共6页 China Resources Comprehensive Utilization
关键词 地埋式污水处理厂 MBR工艺 调试 运行 underground sewage treatment plant MBR process debugging operation
  • 相关文献

参考文献6

二级参考文献18

  • 1Stephenson T,Judd S,Jefferson B,et al.膜生物反应器污水处理技术.张树国,李咏梅译.北京:化学工业出版社,2003.
  • 2Judd S,Judd C.膜生物反应器.陈福泰,黄霞译.北京:科学出版社,2009.
  • 3Ng H Y,Tan T W,Ong S L.Membrane fouling of submerged membrane bioreactors:Impact of mean cell residence time and the contributing factors.Environ.Sci.Technol.2006,40,(8),2706~2713.
  • 4Han S S,Bae T H,Jang G G,et al.Influence of sludge retention time on membrane fouling and bioactivities in membrane bioreactor system.Process Biochem,2005,40:2393~2400.
  • 5Oven G, Bandi M, Howell J A, et al. Economic assessment of membrane processes for water and wastewater treatment [J].Memb Sci,1995,102:77-91.
  • 6Defrance L, Jafrln M Y, Gupm B, et al. Contribution of various constituents of activated sludge to membrane bioreactor fouling[J]. Bio-resource Technology,2000,73:105-112.
  • 7Buisson H, Cote P, Praderie M, et al. The use of immersed membrane for upgrading wastewater treatment plants [J].Wat Sci Technol.,1998,37(9):89-95.
  • 8Witzig R, Manz W, Rosenberger S, et al. Microbiological aspects of a bioreactor with submerged membranes for aerobic treatment of municipal wastewater[J].Wat Res.,2002,36:394-402.
  • 9黄霞,曹斌,文湘华,魏春海.膜-生物反应器在我国的研究与应用新进展[J].环境科学学报,2008,28(3):416-432. 被引量:121
  • 10刘范嘉,乌兰,惠杨杨,刘建阔,薛二军,于静,张卫江,崔静.膜生物反应器强化脱氮除磷的研究进展[J].化工进展,2009,28(6):1071-1075. 被引量:6