期刊文献+

一种HDMI高清座母座连接故障的研究分析与改进

Analysis and Improvement about Connection Fault of One HDMI HD Base
下载PDF
导出
摘要 文章介绍了一种HDMI产品炉后测试时发现HDMI高清座接触不良,经分析为HDMI高清座母座引起,且HDMI高清座母座金手指表面粘染有异物,不良率约15%。作者通过失效分析手段,了解失效产品故障现象,分析故障原因,确定分析手段及方法,找出失效根本原因,并为企业提出了有针对性的改进方案,产品改善后,避免了类似故障的再次发生。 This paper introduces that connection fault was found after furnace test of one HDMI product,the fault was analyzed to be caused by HDMI HD holder,and holder gold finger surface of HDMI HD was stained with foreign matter,the defect rate was about 15%.The Researchers used failure analysis methods,realized the fault phenomenon,analyzed the failure causes,determined the analysis means and methods and find out the root cause of failure.After the manufacturer accepted the suggestion and improved theproduct,the similar failurewas avoided again.
作者 张华 ZHANG hua(Shenzhen Academy of Metrology and Quality Inspection,Shenzhen 518055)
出处 《环境技术》 2023年第7期113-119,131,共8页 Environmental Technology
关键词 HDMI 失效分析 异物 根本原因 HDMI failure analysis foreign matter root cause