摘要
结合实际故障案例,对高速铁路送电初期牵引变电所主变压器跳闸的原因进行分析,并提出故障排查及运行维护的对策。
In connection to the actual cases of faults,the paper analyzes the causes of tripping of main transformer traction substation at the initial stage after power transmission to the high-speed railway and puts forward the countermeasures for troubleshooting and operation maintenance.
出处
《电气化铁道》
2023年第S01期74-78,共5页
Electric Railway
关键词
高速铁路
牵引变电所
主变压器
high-speed railway
traction substation
main transformer