摘要 介绍了提高MNS低压开关柜稳定运行的优化措施,实现了MNS低压抽屉高温告警及支路母线故障紧急切断和隔离功能。为单面MNS低压抽出式开关柜隐患消缺提供了方便,为企业生产系统提供了安全、稳定、高质量供电系统,保障了生产系统的稳定性。 Optimization measures to stabilize the operation of MNS low-voltage switchgear were introduced.The high temperature alarm for MNS low-voltage drawer and the emergency cut-off and isolation functions for branch bus faults had been implemented.It provided convenience for eliminating hidden dangers in single-sided MNS low-voltage withdrawable switchgear,and provided a safe,stable,and high-quality power supply system for enterprise production systems.The stability of the production system was guaranteed.
作者 李爱军 常腾飞 刘晓光 LI Aijun;CHANG Tengfei;LIU Xiaoguang(Shaanxi Beiyuan Chemical Group Co.,Ltd.,Yulin 719319,China)
出处 《聚氯乙烯》 CAS 2023年第8期30-32,共3页 Polyvinyl Chloride
关键词 MNS低压开关柜 插件 断路器 故障 措施 MNS low-voltage switchgear plugins circuit breaker fault measure