摘要
介绍了提高MNS低压开关柜稳定运行的优化措施,实现了MNS低压抽屉高温告警及支路母线故障紧急切断和隔离功能。为单面MNS低压抽出式开关柜隐患消缺提供了方便,为企业生产系统提供了安全、稳定、高质量供电系统,保障了生产系统的稳定性。
Optimization measures to stabilize the operation of MNS low-voltage switchgear were introduced.The high temperature alarm for MNS low-voltage drawer and the emergency cut-off and isolation functions for branch bus faults had been implemented.It provided convenience for eliminating hidden dangers in single-sided MNS low-voltage withdrawable switchgear,and provided a safe,stable,and high-quality power supply system for enterprise production systems.The stability of the production system was guaranteed.
作者
李爱军
常腾飞
刘晓光
LI Aijun;CHANG Tengfei;LIU Xiaoguang(Shaanxi Beiyuan Chemical Group Co.,Ltd.,Yulin 719319,China)
出处
《聚氯乙烯》
CAS
2023年第8期30-32,共3页
Polyvinyl Chloride
关键词
MNS低压开关柜
插件
断路器
故障
措施
MNS low-voltage switchgear
plugins
circuit breaker
fault
measure