介绍了离子膜面电阻测试设备有机玻璃电导池的构造及测试方法,槽电压测试设备复极性实验电解槽的结构特点及测试方法;槽电压、面电阻作为衡量离子膜电化学性能的重要指标,测试方法的选择特别关键;精密的测试设备和正确的测试方法可以为生产和研发提供准确的测试数据。
This article mainly introduces the construction and testing method of plexiglass conductance cell of ion membrane surface resistance testing equipment,the structure characteristics and testing method of the cell voltage testing equipment of complex polarity experimental electrolytic cell;cell voltage and surface resistance are important indicators to measure the electrochemical performance of ionic membranes,the choice of test method is particularly critical;precise test equipment and correct test methods can provide accurate test data for production and research and development.
作者
于修源
张正董
YU Xiu-yuan;ZHANG Zheng-dong(Dongyue Fluorosilicone Science and Technology Group Co.,Ltd.,Huantai 256401,China)
出处
《中国氯碱》
CAS
2023年第8期6-9,63,共5页
China Chlor-Alkali
基金
山东省博士后创新项目专项资金项目(201401002)
“十二五”国家科技支撑计划(2011BAE08B00)。
关键词
有机玻璃电导池
银电极
端板
沟槽
测试夹板
槽电压
阳极电解槽
阴极电解槽
plexiglass conductance cell
silver electrode
end plate
groove
test plate
bath voltage
anode electrolytic cell