以吴桥县工业园区污水处理厂为例,针对其特点,阐述了分布式光伏电站的设计思路。对分布式发电系统组件串联数量、组件串的并联数量、组件阵列方位角倾角以及组件阵列间距进行了科学计算。通过对分布式发电系统发电量的仿真,设计的分布式光伏电站极大程度地满足了污水处理厂提标改造过程中电催化氧化等高耗能设备的用电需求,同时也为分布式光伏发电系统在污水处理厂的实际应用提供了解决方案。
Taking the sewage treatment plant of Wuqiao County Industrial Park as an example,the design idea of distributed photovoltaic power station is expounds according to its characteristics.The number of distributed generation system components in series,the number of parallel components,the azimuth inclination of component array and the spacing of component array are calculated scientifically.Through the simulation of the power generation of the distributed power generation system,the project greatly meets the power demand of high energy consumption equipment such as electrocatalytic oxidation in the upgrading process of sewage treatment plant,and also provides a solution for the practical application of distributed photovoltaic power generation system in sewage treatment plant.
作者
李永康
辛金营
LI Yongkang;XIN Jinying(Beijing Xinrui Electric Co.,Ltd.,Beijing 101100,China;Cangxian Jiedi Hui Ethnic Township Central School,Cangzhou 061725,China)
出处
《现代建筑电气》
2023年第7期10-15,共6页
Modern Architecture Electric
关键词
太阳能
光伏发电
污水处理厂
节能
环保
solar energy photovoltaic system
sewage treatment plant
energy saving
environmental protection