摘要 运动大导风板因其更好的导风效果越来越多的应用在空调产品上,但是,因其导风角度进一步拓展,空调不同运行情况下,房间温度分层情况明显不同,如果采用固定的室内温度补偿值,会存在控温不准的问题。本文通过对运动大导风板空调器在不同导风板角度、内机风档、设定温度下的室温分布进行测量,对运动大导风板的动态温度补偿技术进行了初步探讨。 Multi-turning guide louvers are more and more widely used in air conditioners owning to its greater effect in guiding air.However,the further expansion of angles in guiding air will cause the obviously different indoor temperature stratification under different running states of the air conditioner.Under this circumstance,if a fixed compensation value of the indoor temperature is adopted,it will lead to the inaccurate temperature control.In this paper,the indoor temperature distribution of the multi-turning guide louver in the air conditioner is measured by adjusting angles of the guide louver,settings of the air conditioner internal unit and the set temperature.As a result,a preliminary study is made on the dynamic temperature compensation of multi-turning guide louvers in air conditioners.
作者 王锐锋 彭光前 吴俊鸿 单联瑜 于琦 WANG Ruifeng;PENG Guangqian;WU Junhong;SHAN Lianyu;YU Qi(Xiaomi Technology(Wuhan)Co.,Ltd.,Wuhan 430010,China)
出处 《制冷》 2023年第3期74-78,共5页 Refrigeration
关键词 运动大导风板 室内气流 温度分布 动态补偿 Multi-turning Guide Louvers Indoor Airflow Temperature Distribution Dynamic Compensation
  • 相关文献

参考文献3

二级参考文献16

  • 1周正平,董凯军,刘蔚巍,叶晓江,连之伟.空调房间气流组织与人体热舒适关系的初步探讨[J].制冷空调与电力机械,2006,27(1):17-20. 被引量:10
  • 2周平义 刘彦君.家用中央空调的发展及制约因素[A]..全国暖通空调制冷2000年学术年会资料集[C].,2000.478-481.
  • 3E. Djumaedy, K. W. D. Cheong. Development of a simplified technique of modeling four - way ceiling air supply diffuser. Buiding and environment. 2002,37: 392~ 403.
  • 4Nielsen PV. Description of supply openings in numerical models for room air disribution. ASHRAE transactions 1992,98 ( 1 ):963 ~ 971.
  • 5汤广发 王汉青.小屯站主厂房通风气流优化设计的数值方法[J].湖南大学学报,1988,15(2):128-133.
  • 6TavakkolS,Hosni MH,Miller PL,Straub HE. A study of isothermal throw of air jets with variors room sized and outlet configurations. ASHRAE transactions 1994,100 (1): 1679 ~ 1686.
  • 7DAN I H. Air Distribution for Comfort and IAQ[J].Heating Piping and Air Condition, 1998(5): 90-92.
  • 8FANGER P O. Calculation of Thermal Comfort[J].ASHRAE, 1967,73.
  • 9FANGER P O. Thermal Comfort-Analysis and Applicationin Environmental Engineering[M]. Copenhagen: DanishTechnical Press, 1970.
  • 10臧效罡,赵树兴,李文杰.应用ADPI与PMV评价热舒适性的比较分析[J].山西建筑,2010,36(33):174-175. 被引量:4