摘要 针对导管泵辅助心血管及冠状动脉系统构建了多尺度模型,并对其血流动力学行为进行研究.建立心血管及冠状动脉系统的集总参数模型,宏观分析了导管泵辅助下的心衰合并冠脉狭窄患者的血流动力学参数,并结合计算流体动力学方法研究病理及导管泵辅助下系统的微观流动特性.结果表明:冠状动脉的狭窄程度、狭窄分支对冠状动脉血流影响显著,且左主干狭窄对血流量下降速度影响大于右冠,狭窄部位血流速度及壁面切应力急速上升,并在远心端出现低流速区域以及随狭窄程度加重而增加的涡流等紊流现象;导管泵辅助下冠脉血流量有效提升,一定程度上降低狭窄对血管壁的切应力和流速峰值.导管泵辅助可对心衰合并冠脉狭窄患者的血流动力学参数产生积极影响,具有一定的临床应用价值. A multi-scale model was developed to study the hemodynamic behavior of the cardiovascu-lar and coronary artery system assisted by a catheter pump.The lumped parameter model was established,and the hemodynamic parameters of heart failure patients with coronary stenosis under catheter pump assistance were analyzed macroscopically.The micro-flow characteristics of the system under pathological conditions and catheter pump assistance were studied by using computational fluid dyna-mics(CFD).The results show that the degree of coronary stenosis and stenotic branches have a significant impact on blood flow,and left main artery stenosis has a greater effect on the rate of blood flow reduction than right coronary artery.The blood flow velocity and wall shear stress increase rapidly in the stenotic region,with the appearance of low flow rate area and turbulence phenomenon increasing with the severity of stenosis.Catheter pump assistance effectively increases coronary blood flow and reduces peak wall shear stress and peak flow velocity on the vessel wall caused by stenosis.In conclusion,catheter pump assistance has a positive effect on hemodynamic parameters in heart failure patients with coronary stenosis,and has certain clinical application value.
作者 王芳群 李子健 张志豪 张瑶 朱凤莲 WANG Fangqun;LI Zijian;ZHANG Zhihao;ZHANG Yao;ZHU Fenglian(School of Electrical and Information Engineering,Jiangsu University,Zhenjiang,Jiangsu 212013,China)
出处 《排灌机械工程学报》 CSCD 北大核心 2023年第9期881-887,共7页 Journal of Drainage and Irrigation Machinery Engineering
基金 国家自然科学基金资助项目(51677082)。
关键词 导管泵 血流动力学 脉狭窄 多尺度模型 辅助模式 catheter pump hemodynamic coronary stenosis multi-scale model auxiliary model
  • 相关文献

参考文献10

二级参考文献68

  • 1杨璇,张瑞军.冠状动脉造影为三支或双支病变的心电图临床研究[J].临床心电学杂志,2006,15(3):182-183. 被引量:11
  • 2桑琛,程珂玲,王迪,杭睿杰,李明学.有氧运动对衰老大鼠血清中抗氧化酶和过氧化脂质的影响[J].江苏大学学报(医学版),2007,17(2):128-130. 被引量:10
  • 3覃雁,覃学美.脉搏指示连续心排血量监测技术的临床应用[J].实用心脑肺血管病杂志,2013,21(7):176-177.
  • 4Wilms H, Mittal A, Haydock MD, et al. A systematic re- view of goal directed fluid therapy: rating of evidence for goals and monitoring methods[J]. J Crit Care, 2014,29 (2) :204-209.
  • 5Hadian M, Kim HK, Severyn DA, et al. Cross-comparison of cardiac output trending accuracy of LiDCO, PiCCO, FioTrac and pulmonary artery catheters [J]. Crit Care, 2010,14(6) : R212.
  • 6Zhang Z,Xu X,Yao M,et al. Use of the PiCCO system in critically ill patients with septic shock and acute respirato- ry distress syndrome: a study protocol for a randomized controlled trial[J]. Trials, 2013,14 : 32.
  • 7Bendjelid K, Marx G, Kiefer N, et al. Performance of a new pulse contour method for continuous cardiac output monitoring : validation in critically ill patients[J]. Br J An- aesth,2013,111(4) :573-579.
  • 8Terada T, Maemura Y, Toyoda D, et al. Semi-invasive mo- nitoring of cardiac output in renal transplantation by a new device using arterial pressure waveform analysis compare with intermittent pulmonary thermodilution[J]. Masui, 2010,59 (7) : 897-901.
  • 9Auler J J, Torres ML, Cardoso MM, et al. Clinical evalua- tion of the flotrac/vigileoTM system for continuous cardiac output monitoring in patients undergoing regional anes- thesia for elective cesarean section., a pilot study[J]. Clin- ics (Sao Paulo) ,2010,65(8) :793-798.
  • 10Mclean AS, Huang SJ,Kot M, et al. Comparison of cardi- ac output measurements in critically ill patients:FloTrac/ Vigileo vs transthoracic Doppler echocardiography[J]. Anaesth Intensive Care,2011,39(4) :590-598.

共引文献986

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部