期刊文献+

浅析邯郸市东部第四系地层抗浮水文地质条件——以鑫都汇商业地块项目为例 被引量:1

An analysis of the hydro geological conditions of anti-floating in the Quaternary strata in eastern Handan city——Take the Xinduhui commercial site project as an example
下载PDF
导出
摘要 随着我国社会经济发展水平的不断提高以及现代化城市进程的加速,地下空间不断得到开发利用,大量地下车库、下沉式广场等地下建筑的兴起,尤其是无上部建筑的地下车库、商场、下沉式广场等建筑物,查明场地水文地质条件就成了亟待解决的问题。在邯郸市建筑物基础抗浮工程中,尚未有建筑项目针对抗浮工程开展过专门的水文地质勘察工作。致使由于对建设场地及周边水文地质条件认识的局限和不足,造成抗浮工程造价过高、工程周期延长。以邯郸市东部鑫都汇商业地块项目所在地为典型研究区,通过周边调查及现场钻孔抽水试验等方式进行水文地质勘察,对邯郸市东部第四系地层抗浮水文地质条件进行评价分析。结果表明:邯郸市区处于山前冲洪积平原区,除上部包气带水之外,含水组大致分为0~30 m、30~80 m、80 m以下三段,上部较下部富水,机井单位出水量1.5 m^(3)/h·m,各含水段之间水力联系较为密切;从水文地质勘察成果看,实测场地周边地下水水位标高在+40.111 m~+43.244 m之间;对场地地基可能产生影响的地下水为包气带水和浅层水,可划分为②层粉土弱透水含水段、③-⑥层粉质粘土及粉土极微-中等透水含水段、⑦层细砂及粉砂中等透水含水段三个含水段。分析结论为地下空间开发利用提供可靠技术支撑。 With the continuous improvement of China’s socioeconomic development level and the acceleration of the modern urban process,underground space is constantly being developed and utilised,and a large number of underground buildings such as underground garages and sunken squares are emerging,especially underground garages,shopping malls,sunken squares and other buildings without superstructures,identifying the hydro-geological conditions of the site has become an urgent problem.No construction project in Handan has yet carried out a special hydro-geological investigation for anti-floatation engineering on building foundations.This has resulted in high costs and prolonged construction periods due to limitations and inadequate knowledge of the construction site and surrounding hydro-geological conditions.The site of the Xinduhui commercial plot project in the eastern part of Handan City was taken as a typical study area,and hydro-geological investigations were carried out by means of perimeter surveys and on-site borehole pumping tests to evaluate and analyse the float-resistant hydro-geological conditions of the Quaternary strata in the eastern part of Handan City.The results show that:the urban area of Handan is in the pre-hill alluvial plain area,except for the upper part of the packaged gas belt water,the water-bearing group is roughly divided into three sections from 0 to 30 m,30 to 80m and below 80m,the upper part is more water-rich than the lower part,the water output of the machine well unit is 1.5 m^(3)/h·m,and the water-bearing sections are more closely connected with each other hydraulically;From the results of the hydro-geological survey,the measured groundwater level elevation around the site ranges from+40.111 m to+43.244 m;The groundwater that may have an impact on the foundation of the site is water in the air pocket and shallow water,which can be divided into three water-bearing sections,②Vol.45 NO.4 layer of powdered soil with weak permeability,③-⑥layer of powdered clay and powdered soil with very slight-medium permeability,and⑦layer of fine sand and powdered sand with medium permeability.The conclusions of the analysis provide reliable technical support for the development and use of underground space.
作者 伊浩然 李鹏 吴涛 赵延超 YIN Hao-ran;LI Peng;WU Tao;ZHAO Yan-chao(China Coal Land Huasheng Hydro-geological Survey Company Limited,Handan 056004,Hebei;Hydro-geology,Engineering,Geology and Environmental Geology Survey Institute,China Coal Geological Administration,Handan 056000,Hebei)
出处 《地下水》 2023年第4期13-17,33,共6页 Ground water
基金 邯郸市科学技术研究与发展计划项目资助(21112903026)。
关键词 邯郸市 第四系地层 抗浮工程 水文地质条件 Handan city Quaternary strata Anti-floating project Hydro geological conditions
  • 相关文献

参考文献4

二级参考文献41

共引文献95

同被引文献6

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部