期刊文献+

气相色谱法测定清肠栓中樟脑残留量和冰片含量 被引量:1

Determination of camphor residue and borneol content in Qingchang suppository by GC
下载PDF
导出
摘要 目的建立清肠栓中樟脑残留物和冰片含量的气相测定方法。方法采用气相色谱法,色谱柱为Agilent毛细管柱(30 m×0.25 mm×0.25µm),柱温为140℃,进样口温度250℃,检测器(FID)温度为250℃。结果樟脑、龙脑和异龙脑在0.0299~1.497µg(r=1.000)、0.0205~1.025µg(r=1.000)、0.0097~0.4830µg(r=1.000)范围内呈现良好的线性关系。精密度、稳定性、重复性试验结果的RSD均小于2%,平均加样回收率分别为99.7%、101.0%、102.5%。结论该方法准确、可靠、简便快速,可用于清肠栓中龙脑含量的测定。 Objective To establish a gas chromatography for simultaneous determination of camphor residue and borneolum content in Qingchang Suppository.Methods Gas chromatograph method was used.The chromatographic column was Agilent capillary column(30 m×0.25 mm×0.25μm).The column temperature was 140℃.The sample injection temperature was 250℃.The FID detector temperature was 250℃.Results Camphor,borneol and isoborneol content showed good linear in the extent of 0.0299~1.497(r=1.000),0.0205~1.025(r=1.000),0.0097~0.4830μg(r=1.000).RSDs of precision,stability and repeatability test results were less than 2%.The recovery was 99.7%,101.0%,102.5%.Conclusion This method is simple and quick with accurate result,which could be used for the content determination of Borneol in Qingchang Suppository.
作者 潘宇炯 何志高 周昕 章恒周 杨月红 黄景山 PAN Yujiong;HE Zhigao;ZHOU Xin;ZHANG Hengzhou;YANG Yuehong;HUANG Jingshan(Longhua Hospital Shanghai University of Traditional Chinese Medicine,Shanghai 200032 China;Shanghai Wanshicheng Pharmaceutical limited,Shanghai 201507 China)
出处 《药学实践与服务》 CAS 2023年第9期552-556,共5页 Journal of Pharmaceutical Practice and Service
基金 上海市进一步加快中医药传承创新发展三年行动计划(ZY(2021-2023)-0203-01)。
关键词 气相色谱法 清肠栓 樟脑 龙脑 异龙脑 含量测定 GC Qingchang suppository camphor borneol isoborneol content determination
  • 相关文献

参考文献13

二级参考文献193

共引文献208

同被引文献11

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部