基于重力热管的建筑屋面热开关式隔热层

Building roof thermal switch type insulation layer based on gravity heat pipe
下载PDF
导出
摘要 在建筑屋面铺设隔热层是目前广泛采用的一种建筑节能施工方法。以北京地区某建筑为例进行计算分析发现,隔热层的高热阻在夜间不利于建筑屋面白天积累的热量向外界排散。针对这一问题,提出一种基于铜水重力热管的建筑屋面热开关式隔热层,在白天隔热层上表面温度较高的时段热管不启动,在夜间隔热层上表面温度低于建筑屋面结构的时段热管启动,把建筑屋面结构的热量快速传到隔热层外表面向外界排散,减少了热量传入室内的比例。计算结果表明,按照间隔0.3 m铺设重力热管的热开关式隔热层比普通隔热层的空调制冷量下降14.4%,节能效果明显。 Laying insulation layer on building roof is a widely used building energy saving construction method at present.Taking a building in Beijing as an example,it is found that the high thermal resistance of the insulation layer at night is not conducive to the dissipation of heat accumulated in the building roof during the day to the outside.To solve this problem,a thermal switch type heat insulation layer of building roof based on copper water gravity heat pipe is proposed.The heat pipe does not start during the day when the surface temperature of the insulation layer is high,but starts during the night when the surface temperature of the insulation layer is lower than that of the building roof structure.The heat of the building roof structure is quickly transferred to the exterior surface of the insulation layer and dissipated to the outside,reducing the proportion of heat into the room.The calculation results show that the cooling capacity of air conditioning of the ordinary insulation layer is reduced by 14.4%by the thermal switch insulation layer laid with the gravity heat pipe at an interval of 0.3 m,and the energy saving effect is obvious.
作者 柴国荣 陈婕 王伟红 CHAI Guorong;CHEN Jie;WANG Weihong(Patent Office,State Intellectual Property Office,Beijing 100088,China)
出处 《新型建筑材料》 2023年第9期106-109,121,共5页 New Building Materials
关键词 建筑节能 隔热层 重力热管 building energy conservation insulation layer gravity heat pipe
  • 相关文献

参考文献6

二级参考文献30

共引文献28

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部