摘要
对隔声砂浆兼具找平和隔声功能,直接取代铺砖用的干硬性水泥砂浆的隔声砂浆楼板系统的材料性能、楼板隔声性能和长期使用性能进行研究。结果表明该隔声砂浆楼板隔声系统长期使用性能较差,易出现起拱起翘和空鼓断裂。建议隔声砂浆使用时,应在隔声砂浆层做C20以上的混凝土保护层。
The material performance,floor sound insulation performance and long-term service performance of the sound insulation mortar floor system was studied,which had both leveling and sound insulation functions and directly replaces the cement mortar used for laying bricks.The results showed that this sound insulation mortar floor system has poor long-term performance,and was prone to warping and hol-lowing fracture.It is recommended that when using sound insulation mortar,a concrete protective layer of C20 or above should be added to the sound insulation mortar layer.
作者
江飞飞
麦粤帮
蓝志江
李密
张二进
JIANG Feifei;MAI Yuebang;LAN Zhijiang;LI Mi;ZHANG Erjin(Guangdong Provincial Academy of Building Research Group Co.,Ltd.Guangzhou 510500,China;Zhuhai Construction Quality and Safety Supervision Station Zhuhai 519099,China)
出处
《广东土木与建筑》
2023年第9期117-119,共3页
Guangdong Architecture Civil Engineering
基金
珠海市建设科技促进中心课题(建筑楼板隔声技术应用研究JKHT2022ST0001)。
关键词
隔声砂浆
隔声砂浆楼板系统
长期使用性能
撞击声隔声
sound insulation mortar
sound insulation mortar floor system
long-term performance
impact sound insulation