摘要 介绍了炼钢厂连铸区域大包旋转塔驱动减速齿轮轴重复出现断裂故障,针对这种情况对齿轮轴的强度进行效验,发现危险截面安全系数小于许用安全系数,轴强度不足,并提出增大轴径的改进措施,取得了较好的使用效果。 This paper mainly introduces the repeated failure of the drive reduction gear shaft in the continuous casting area of the steel mill.To solve this problem,the strength of the gear shaft is tested effectively.It is found that the safety factor of the dangerous section is less than the allowable safety factor and the shaft strength is insufficient.Measures to increase the shaft diameter are put forward by the researchers,and good results are obtained.
作者 白华 章勤奋 都胜朝 金明勇 陈建平 Bai Hua;Zhang Qinfen;Du Shengchao;Jin Mingyong;Chen Jianping(Equipment Management Department,Wuhan Iron and Steel Co.,Ltd.Wuhan 430083,Hubei;Steeling Making Plant of Wuhan Iron and Steel Co.,Ltd.Wuhan 430083,Hubei)
出处 《武汉工程职业技术学院学报》 2023年第3期16-19,共4页 Journal of Wuhan Engineering Institute
关键词 旋转塔 减速机 断裂 强度 安全系数 rotating tower reducer break strength safety factor