摘要 大南湖一矿利用CO引排系统治理回风隅角CO超限,为达到CO治理效果的同时,避免采空区自然发火,引排系统水环真空泵的设计尤为关键。以煤矿瓦斯抽采工程设计标准为参考,现场进行试验调整,确定合理的CO引排系统管路及水环真空泵相关参数。根据设计计算,CO低负压引排系统管路采用Φ610 mm×5000mm型螺旋焊接钢管,引排泵采用2台型号2BEC72型水环真空泵,抽气量大于515.6m^(3)/min。 Dananhu No.1 Mine uses the CO drainage system to govern the return air corner CO exceeding the limit.In order to achieve the CO govern effect and avoid spontaneous combustion in the goaf at the same time,the design of the water ring vacuum pump of the drainage system is particularly important.Taking the design standards for coal mine gas drainage engineering as a reference,on-site experiments are conducted to adjust and determine the reasonable CO drainage system pipeline and relevant parameters of water ring vacuum pump.According to design calculations,the CO low negative pressure drainage system pipeline adoptsΦ610 mm×5000 mm type spiral welded steel pipe,two 2BEC72 type water ring vacuum pumps are used for the drainage pumps,with a suction amount greater than 515.6 m^(3)/min.
作者 路宁 张海洋 王永敬 Lu Ning;Zhang Haiyang;Wang Yongjing(State Grid Energy Hami Coal Electricity Co.,Ltd.Dananhu No.1 Mine,Xinjiang Hami 839000;China Coal Technology and Engineering Group Shenyang Research Institute Co.,Ltd.,Liaoning Fushun 113122;State Key Laboratory of Coal Mine Safety Technology,Liaoning Fushun 113122)
出处 《山东煤炭科技》 2023年第9期125-127,130,共4页 Shandong Coal Science and Technology
关键词 工作面 回风隅角 CO引排 水环真空泵 系统管路 working face return air corner CO drainage water ring vacuum pump system pipeline
  • 相关文献

参考文献9

二级参考文献103

共引文献84

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部